๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Chemical-shift imaging: A hybrid approach

โœ Scribed by M. Doyle; P. Mansfields


Publisher
John Wiley and Sons
Year
1987
Tongue
English
Weight
370 KB
Volume
5
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


The hybrid technique of projection-reconstruction echo-planar (PREP) imaging for obtaining chemical-shift images is demonstrated experimentally using a fluorine sample. The technique which is a variation on echo-planar imaging (EPI) relies on a multipass procedure. It is nevertheless quite efficient and consequently chemical-shift images may be produced in a few minutes. The method produces images in 64 chemical-shift regions, each region mapped spatially by 64 X 64 pixels. The imaging time was just over 4 min. These 64 chemical-shifted images can be straightforwardly added together to form an undistorted image of the complete object. In addition the chemical-shift spectrum can be extracted and the various chemical-shift images can be unambiguously assigned to the spectral peaks.


๐Ÿ“œ SIMILAR VOLUMES


Echoplanar chemical shift imaging
โœ A.R. Guimaraes; J.R. Baker; B.G. Jenkins; P.L. Lee; R.M. Weisskoff; B.R. Rosen; ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 140 KB
A Method for Chemical-Shift-Selective Im
โœ Charles L. Dumoulin ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 213 KB

Selective suppression of a given resonance in an NMR image can be obtained with a i ~/ 2 pulse whose excitation spectrum is zero at the appropriate chemical shift. The selective 7r/2 pulse presented here is composed of two nonselective i ~/ 2 pulses of opposite phase. The two pulses are separated by

PEEPโ€”A rapid chemical-shift imaging meth
โœ D. N. Guilfoyle; A. Blamire; B. Chapman; R. J. Ordine; P. Mansfield ๐Ÿ“‚ Article ๐Ÿ“… 1989 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 292 KB

The phase-encoded echo-planar (PEEP) technique, a variant of echo-planar imaging, is used to achieve simultaneous high-speed spatial and chemical-shift data acquisition. This technique is the 2DFT equivalent of the projection reconstruction echo-planar method for chemical-shift imaging. Examples of

Fast gradient-echo chemical-shift imagin
โœ H. W. Park; Y. H. Kim; Z. H. Cho ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 285 KB

A fast chemical-shift imaging using the gradient-echo technique is proposed for the separation of the water and fat in human in vivo imaging. This technique also incorporates magnetic field inhomogeneity correction in the fast chemical-shift imaging. Experimental results of the proposed imaging tech

Chemical shift imaging with spectrum mod
โœ Li An; Qing-San Xiang ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 225 KB

A new chemical shift imaging technique was developed to efficiently obtain separate images for multiple chemical shift peaks from a set of spin-echo acquisitions. Information from localized NMR spectroscopy was used to model the chemical shift spectrum as sharp peaks with known resonance frequencies