## Abstract Hypointense band artifacts occur at intersections of nonparallel imaging planes in rapidly acquired MR images; quantitative or numerical analysis of these bands and strategies to mitigate their appearance have largely gone unexplored. The magnetization evolution in the different regions
Characterization and reduction of the transient response in steady-state MR imaging
β Scribed by Brian A. Hargreaves; Shreyas S. Vasanawala; John M. Pauly; Dwight G. Nishimura
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 253 KB
- Volume
- 46
- Category
- Article
- ISSN
- 0740-3194
- DOI
- 10.1002/mrm.1170
No coin nor oath required. For personal study only.
β¦ Synopsis
Refocused steady-state free precession (SSFP) imaging sequences have recently regained popularity as faster gradient hardware has allowed shorter repetition times, thereby reducing SSFP's sensitivity to off-resonance effects. Although these sequences offer fast scanning with good signal-to-noise efficiency, the "transient response," or time taken to reach a steady-state, can be long compared with the total imaging time, particularly when using 2D sequences. This results in lost imaging time and has made SSFP difficult to use for real-time and cardiac-gated applications. A linear-systems analysis of the steady-state and transient response for general periodic sequences is shown. The analysis is applied to refocused-SSFP sequences to generate a two-stage method of "catalyzing," or speeding up the progression to steady-state by first scaling, then directing the magnetization. This catalyzing method is compared with previous methods in simulations and experimentally. Although the second stage of the method exhibits some sensitivity to B(1) variations, our results show that the transient time can be significantly reduced, allowing imaging in a shorter total scan time. Magn Reson Med 46:149-158, 2001.
π SIMILAR VOLUMES
Centrifugation was applied to study the transport phenomena in various suspensions of charged colloidal silica particles. Isopycnic focusing of colored density marker beads was used to view the evolution of the density gradient and to determine its steady-state shape from the measured positions of t
Figure 3 Radiation pattern of the antenna configuration in different planes. αα s 0Π, α α α α s 45Π, ΠΈ ΠΈ ΠΈ ΠΈ ΠΈ ΠΈ s 90Π, α ΠΈ α ΠΈ α ΠΈ s 135Π Figure 4 S of the proposed antenna configuration along the 21 boresight with respect to that of a standard circular microstrip antenna operating in the TM mode 1