𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Changes in knee adduction moment, pain, and functionality with a variable-stiffness walking shoe after 6 months

✍ Scribed by Jennifer C. Erhart; Annegret Mündermann; Barbara Elspas; Nicholas J. Giori; Thomas P. Andriacchi


Publisher
Elsevier Science
Year
2010
Tongue
English
Weight
136 KB
Volume
28
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

This study tested the effects of variable‐stiffness shoes on knee adduction moment, pain, and function in subjects with symptoms of medial compartment knee osteoarthritis over 6 months. Patients were randomly and blindly assigned to a variable‐stiffness intervention or constant‐stiffness control shoe. The Western Ontario and McMaster Universities (WOMAC) score served as the primary outcome measure. Joint loading, the secondary outcome measure, was assessed using the external knee adduction moment. Peak external knee adduction moment, total WOMAC, and WOMAC pain scores were assessed at baseline and after 6 months. The total WOMAC and WOMAC pain scores for the intervention group were reduced from baseline to 6 months (p = 0.017 and p = 0.002, respectively), with no significant reductions for the control group. There was no difference between groups in magnitude of the reduction in total WOMAC (p = 0.50) or WOMAC pain scores (p = 0.31). The proportion of patients achieving a clinically important improvement in pain was greater in the intervention group than in the control group (p = 0.012). The variable‐stiffness shoes reduced the peak knee adduction moment (−6.6% vs. control, p < 0.001) in the 34 intervention subjects at 6 months. The adduction moment reduction significantly improved (p = 0.03) from the baseline reduction. The constant‐stiffness control shoe increased the peak knee adduction moment (+6.3% vs. personal, p = 0.004) in the 26 control subjects at 6 months. The results of this study showed that wearing the variable‐stiffness shoe lowered the adduction moment, reduced pain, and improved functionality after 6 months of wear. The lower adduction moment associated with wearing this shoe may slow the rate of progression of osteoarthritis after long‐term use. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:873–879, 2010


📜 SIMILAR VOLUMES


Effect of variable-stiffness walking sho
✍ Jennifer C. Erhart-Hledik; Barbara Elspas; Nicholas J. Giori; Thomas P. Andriacc 📂 Article 📅 2011 🏛 Elsevier Science 🌐 English ⚖ 257 KB

## Abstract This study investigated the load‐modifying and clinical efficacy of variable‐stiffness shoes after 12 months in subjects with medial compartment knee osteoarthritis. Subjects who completed a prior 6‐month study were asked to wear their assigned constant‐stiffness control or variable‐sti

Changes in in vivo knee loading with a v
✍ Jennifer C. Erhart; Chris O. Dyrby; Darryl D. D'Lima; Clifford W. Colwell; Thoma 📂 Article 📅 2010 🏛 Elsevier Science 🌐 English ⚖ 198 KB

## Abstract External knee adduction moment can be reduced using footwear interventions, but the exact changes in in vivo medial joint loading remain unknown. An instrumented knee replacement was used to assess changes in in vivo medial joint loading in a single patient walking with a variable‐stiff