## Abstract This study tested the effects of variable‐stiffness shoes on knee adduction moment, pain, and function in subjects with symptoms of medial compartment knee osteoarthritis over 6 months. Patients were randomly and blindly assigned to a variable‐stiffness intervention or constant‐stiffnes
Changes in in vivo knee loading with a variable-stiffness intervention shoe correlate with changes in the knee adduction moment
✍ Scribed by Jennifer C. Erhart; Chris O. Dyrby; Darryl D. D'Lima; Clifford W. Colwell; Thomas P. Andriacchi
- Publisher
- Elsevier Science
- Year
- 2010
- Tongue
- English
- Weight
- 198 KB
- Volume
- 28
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
External knee adduction moment can be reduced using footwear interventions, but the exact changes in in vivo medial joint loading remain unknown. An instrumented knee replacement was used to assess changes in in vivo medial joint loading in a single patient walking with a variable‐stiffness intervention shoe. We hypothesized that during walking with a load modifying variable‐stiffness shoe intervention: (1) the first peak knee adduction moment will be reduced compared to a subject's personal shoes; (2) the first peak in vivo medial contact force will be reduced compared to personal shoes; and (3) the reduction in knee adduction moment will be correlated with the reduction in medial contact force. The instrumentation included a motion capture system, force plate, and the instrumented knee prosthesis. The intervention shoe reduced the first peak knee adduction moment (13.3%, p = 0.011) and medial compartment joint contact force (12.3%; p = 0.008) compared to the personal shoe. The change in first peak knee adduction moment was significantly correlated with the change in first peak medial contact force (R^2^ = 0.67, p = 0.007). Thus, for a single subject with a total knee prosthesis the variable‐stiffness shoe reduces loading on the affected compartment of the joint. The reductions in the external knee adduction moment are indicative of reductions in in vivo medial compressive force with this intervention. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1548–1553, 2010
📜 SIMILAR VOLUMES
## Abstract This study investigated the load‐modifying and clinical efficacy of variable‐stiffness shoes after 12 months in subjects with medial compartment knee osteoarthritis. Subjects who completed a prior 6‐month study were asked to wear their assigned constant‐stiffness control or variable‐sti