𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Ceramic Femoral Heads for Total Hip Arthroplasty

✍ Scribed by G. Willmann


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
387 KB
Volume
2
Category
Article
ISSN
1438-1656

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


The wear of a polyethylene socket articu
✍ Hamada, Yoshiki ;Horiuchi, Tadahiro ;Sano, Yayoi ;Usui, Ikuo πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 515 KB

Wear of yttria-zirconia (zirconia) in the femoral head was investigated in mature mongrel dogs weighing 10 to 13 kg. Two dogs, which were used as a control group, were sacrificed 18 months after implantation of the uncemented modular hip system with an alumina ceramic (alumina) femoral head. A zirco

Testing of silicon nitride ceramic beari
✍ B. Sonny Bal; Ashok Khandkar; R. Lakshminarayanan; Ian Clarke; Aaron A. Hoffman; πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 415 KB

## Abstract Modern ceramic bearings used in total hip arthroplasty (THA) consist of a femoral head (ball) articulating inside a hemispherical acetabular cup (socket); the ball and socket are made of alumina (Al~2~O~3~) and Al~2~O~3~‐based composite materials. In the present study, total hip bearing

Femoral cementing technique for hip resu
✍ Rudi G. Bitsch; Christian Heisel; Mauricio Silva; Thomas P. Schmalzried πŸ“‚ Article πŸ“… 2007 πŸ› Elsevier Science 🌐 English βš– 448 KB

## Abstract The resurgence of metal–metal bearings has renewed interest in hip resurfacing, but a paucity of information exists regarding femoral cementing technique. We developed a laboratory model in which 72 open‐cell foam specimens were used to simulate bone. Analyses of two cement viscosities,

In vitro testing of Al2O3–Nb composite f
✍ M.N. Rahaman; T. Huang; B.S. Bal; Y. Li πŸ“‚ Article πŸ“… 2010 πŸ› Elsevier Science 🌐 English βš– 567 KB

Alumina (Al 2 O 3 ) bearings in total hip arthroplasty lead to low wear rates, but catastrophic failure of Al 2 O 3 femoral heads, while rare, remains a concern. In the present work, a composite of Al 2 O 3 and niobium (Nb) was tested in vitro for potential use as an alternative femoral head materia

Characterization ofin vivo wear debris f
✍ Lerouge, S. ;Huk, O. ;Yahia, L'H. ;Sedel, L. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 746 KB

In contrast to the much-studied mechanism of aseptic loosening of the metal-polyethylene joint couple, the mechanism responsible for failure of ceramic-ceramic (CC) total hip arthroplasties (THAs) has not been evaluated. The aim of this study was to conduct a systematic characterization of the in ui