## Enhancement of electroosmotic flow in capillary electrochromatography A major impediment to enhancing the speed of separation in capillary electrochromatography (CEC) is the upper limit on the electroosmotic flow (EOF) velocity by the maximal zeta potential of the chromatographic surface. Here,
Capillary electrochromatography with segmented capillaries for controlling electroosmotic flow
β Scribed by Changming Yang; Ziad El Rassi
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 113 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
β¦ Synopsis
Capillaries consisting of two segments each packed with a different stationary phase were introduced for the control and manipulation of the electroosmotic flow (EOF) in capillary electrochromatography (CEC). This kind of column configuration was called segmented capillary where one segment was packed with octadecyl silica (ODS) and served as the separation segment while the other segment was packed with bare silica and functioned as the EOF accelerator segment. The average flow in the segmented capillary increased linearly with increasing fractional length of the EOF accelerator segment, and consequently the analysis time was reduced. Under a given set of conditions, the average flow can be varied over a certain range that extends from the EOF in the individual ODS capillary at the lower end to the EOF in the individual bare silica capillary at the higher end. The pore size of the bare silica in the EOF accelerator segment influenced the average flow in the segmented capillary. Because of the difference in the EOF of the individual segments, the average flow across the segmented capillary is partially degenerated from EOF to viscous flow. Furthermore, the retaining frits in CEC columns are restrictive points which slow down the average flow, thus furthering the degeneration of the flow from EOF to viscous flow. In other words, in CEC columns containing retaining frits, the flow of the mobile phase is not only based on electroosmosis but is contaminated by a viscous component.
π SIMILAR VOLUMES
Fused-silica capillaries often lack long-term stability and control of electroosmotic flow in capillary electrophoresis owing to the reactivity of the bulk silica structure in aqueous solutions of high or low pH. Polypropylene hollow fibers, an alternative to fused silica, have been chemically modif
Nonaqueous capillary electrophoresis (NACE) is a powerful tool for the analysis of surface-active substances, which represent a broad class of analytes containing cationic and anionic species, such as surfactants, phosphoric acid esters, and amines. In order to conduct an efficient method developmen
A method for controlling the electroosmotic flow EOF in a capillary is reported using radial electric fields which vary along the length of the separation capillary. The magnitude of the control is compared to the control achieved using radial fields which remain constant along the length of the cap