𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Canine bone blood flow estimated with microspheres

✍ Scribed by Guoping Li; James T. Bronk; Dr. Patrick J. Kelly


Publisher
Elsevier Science
Year
1989
Tongue
English
Weight
602 KB
Volume
7
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Blood flow rate in the periosteal and endosteal cortices of the diaphysis of long bones was determined in eight anesthetized adult dogs using the radioactively labeled microsphere method. The flow rate in endosteal and periosteal cortices is not significantly different unless the endosteal cortex contains cancellous bone from the medullary cavity. The highest flow rate is in the ulna, with 6.50 ml/min/100 g for the endosteal cortex and 5.15 mYmid100 g for the periosteal cortex. The lowest flow rate is in the femur, with 2.89 ml/mid100 g for the endosteal cortex and 2.29 ml/min/100 g for the periosteal cortex. The results of this study indicate that variation of blood flow does exist between bones of dogs. However, the flow rates of individual bone on the left and right sides in the same dog are not significantly different. This indicates that the data are reproducible and reliable, and differences are not an inaccuracy of the radioactively labeled microsphere method. The results also demonstrate that there are no signifcant differences in bone blood flow as measured with small numbers (fewer than 400 microspheres per sample) and large numbers (more than 400 microspheres per sample) of microspheres. The adequate number of microspheres in each bone sample is 150-250. Therefore, a dose of 0.5 x lo6 spheredkg body weight can be sufficient.


πŸ“œ SIMILAR VOLUMES


Laser doppler flowmetry for estimation o
✍ Dr. Gunnar Schwarz Lausten; Thomas KiΓ¦r; Benny Dahl πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 764 KB

## Abstract The blood flow in the femoral condyles of six pigs was measured by the microsphere technique and by laser Doppler flowmetry (LDF) before and after clamping of the external iliac artery. A significant decrease in the bone blood flow was found with both microsphere and LDF measurements, a

Laser doppler flowmetry for bone blood f
✍ Dr. Marc F. Swiontkowski; S. Tepic; S. M. Perren; R. Moor; R. Ganz; B. A. Rahn πŸ“‚ Article πŸ“… 1986 πŸ› Elsevier Science 🌐 English βš– 851 KB

Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral head and femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and 85Sr-labeled microspheres were made in an adult rabbit model. There was

Blood flow evaluation of vascularized bo
✍ John J. Siegert; Dr. Michael B. Wood πŸ“‚ Article πŸ“… 1990 πŸ› Elsevier Science 🌐 English βš– 572 KB

## Abstract Blood flow in vascularized bone transfers was evaluated in a canine model. Cortical bone blood flow was determined in undisturbed control bone, vascularized heterotopic bone transfers, and nonvascularized cortical bone grafts by means of the radionuclide‐labeled microsphere technique. F

Dynamic radioisotope bone imaging as a n
✍ Richard W. Nutton; Robert H. Fitzgerald Jr.; Manuel L. Brown; Dr. Patrick J. Kel πŸ“‚ Article πŸ“… 1984 πŸ› Elsevier Science 🌐 English βš– 760 KB

The relative values of dynamic and static bone imaging with hydroxymethylenediphosphonate technetium 99m (99mTc HDP) as an indicator of bone blood flow was investigated in the tibia of mature dogs. The dynamic bone scan consisted of 60 1-s images formed after the intravenous injection of w m T ~ HDP

Heterogeneity of blood flow in tibial co
✍ S. M. Willans; Dr. I. D. McCarthy πŸ“‚ Article πŸ“… 1991 πŸ› Elsevier Science 🌐 English βš– 467 KB

## Abstract The distribution of tibial blood flow was measured by injecting approximately (600–1000) X 10^3^ 15 ΞΌ microspheres, labelled with either tin‐113 (^113^Sn) or cobalt‐57 (^57^Co) into femoral arteries of five mature greyhounds. The diaphyseal cortex, stripped of periosteum and devoid of m