A gradient-echo line scan imaging technique was developed which employs two-dimensional spatially selective radiofrequency (2DRF) pulses for consecutively exciting individual columns of transverse magnetization, i.e., image lines. Although a variety of trajectories are possible for 2DRF excitation,
Calibration of echo-planar 2D-selective RF excitation pulses
✍ Scribed by Markus Oelhafen; Klaas P. Pruessmann; Sebastian Kozerke; Peter Boesiger
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 954 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Echo‐planar radiofrequency (RF) pulses (EPP) are increasingly being used for 2D‐selective excitation in MRI. Pulse schemes of this kind are susceptible to eddy‐current effects, timing imperfections, and anisotropy of the gradient system. As a consequence, practical EPP implementations have been restricted to robust fly‐back strategies that use only every other leg of the echo‐planar trajectory for RF transmission. The present work is dedicated to enabling forward‐backward EPP with RF transmission during each k‐space segment, hence doubling the pulses' time efficiency. This is accomplished by comprehensive pulse calibration based on preparatory measurements of the system imperfections, including potential gradient anisotropy. The effectiveness of the method is demonstrated in vitro and in vivo. By doubling the speed of k‐space coverage, the proposed method enhances the potential of EPP for numerous applications. For example, motion‐sensitive techniques benefit from shorter feasible echo times (TEs) and improved excitation profiles resulting from reduced in‐pulse motion. In sequences with fast repetition, shorter EPP help reduce the overall scan duration. Alternatively, the higher time efficiency of forward‐backward EPP can enhance their spatial selectivity. Magn Reson Med 52:1136–1145, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Traditional __T__~2~‐based imaging techniques are geared toward imaging long‐__T__~2~, species. Traditional techniques are, therefore, not optimal in clinical situations where the information of interest lies in the short‐__T__~2~ species. __T__~2~‐selective RF excitation (TELEX) is a t
## Abstract ## Purpose: To demonstrate the feasibility of two‐dimensional selective radio frequency (2DRF) excitations for fast‐spin‐echo imaging of inner fields‐of‐view (FOVs) in order to shorten acquisitions times, decrease RF energy deposition, and reduce image blurring. ## Materials and Metho
## Abstract Multifrequency selective excitation and inversion were recently described and tested for multislice imaging and multivolume selective spectroscopy (__Magn. Reson. Med.__ 6, 364 (1988), __J. Magn. Reson.__ 76, 155 (1988)). The technique is based on the assumption that a multifrequency rf