𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Calibration of a Raman spectrometer using the Kr+ laser plasma lines

✍ Scribed by C. Julien; C. Hirlimann


Publisher
John Wiley and Sons
Year
1980
Tongue
English
Weight
319 KB
Volume
9
Category
Article
ISSN
0377-0486

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

We show that the plasma lines of a Kr^+^ laser can be used for the calibration of a Raman spectrometer. We have tabulated the absolute values of the plasma lines as well as the shift of these lines relative to the laser lines.


πŸ“œ SIMILAR VOLUMES


Behaviour of the calibration of a Raman
✍ Abdelkader Mestari; Robert GaufrΓ¨s; Patrice Huguet πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 200 KB

In connection with indirect Raman di †erence spectroscopy, a method which has been suggested for measuring Raman wavenumber shifts between two di †erent samples with a multi-channel spectrometer, the behaviour of the calibration of the spectrometer with temperature changes was studied. The aim of th

Absolute Ξ½2 Line Intensities of HOCl by
✍ J. Vander Auwera; J. Kleffmann; J.-M. Flaud; G. Pawelke; H. BΓΌrger; D. Hurtmans; πŸ“‚ Article πŸ“… 2000 πŸ› Elsevier Science 🌐 English βš– 349 KB

We have measured absolute line intensities in the 2 fundamental band at 1238 cm Οͺ1 of both isotopomers of hypochlorous acid, HOCl. To obtain the partial pressure of the species in the sample mixture, unavailable through direct measurement since HOCl exists only in equilibrium with H 2 O and Cl 2 O a

Detection and Analysis of Strong Oscilla
✍ V. S. Belyaev; A. S. Kurilov; A. P. Matafonov; V. I. Vinogradov; V. S. Lisitsa; πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 407 KB πŸ‘ 1 views

## Abstract X‐ray lines of ions in a solid target interacting with picosecond laser pulses of the intensity ∼3 Γ— 10^17^ W/cm^2^ were studied on the β€œNeodim” laser facility. We observed X‐ray Ly~__Ξ±__~ emission spectra of hydrogen‐like fluorine ions. Satellite lines were also recorded, evidencing th

A new approach to the effective preparat
✍ Jianmei Ding; Uwe D. Neue πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 151 KB πŸ‘ 3 views

A procedure that permits rapid development of an optimized solid phase extraction (SPE) method for the analysis of drugs in plasma by on-line solid phase extraction-mass spectrometry (SPE-MS) has been developed. This procedure employs the concept of manipulating the pH and the percentage of organic