𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Calculation of the Electron Efficiency for a Two-Cavity Gyroklystron Amplifier by Using a Self-Consistent Code

✍ Scribed by Geng, Zhi-Hui ;Liu, Pu-Kun


Book ID
111585966
Publisher
Springer
Year
2004
Tongue
English
Weight
232 KB
Volume
25
Category
Article
ISSN
0195-9271

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


A model for self-consistent cluster calc
✍ B. Cartling; B. Roos; U. Wahlgren πŸ“‚ Article πŸ“… 1973 πŸ› Elsevier Science 🌐 English βš– 451 KB

It is shown that essential Features of the band structure of a. covalent crystal, as silicon, emerge in the level scheme of a cluster calculation utilizing the SCF Xa scattered wave method. 'The model cluster was terminated by a layer of saturating atoms to take care or the dangling bonds and the po

Calculation of self-impedance and radiat
✍ Jian Yang; Jan Carlsson; Per-Simon Kildal; Charlie Carlsson πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 275 KB πŸ‘ 1 views

## Abstract We present a computation method for the self‐impedance and radiation efficiency of a dipole near a lossy dielectric cylinder with arbitrary cross section by using a spectrum of two‐dimensional (2‐D) solutions. The 2‐D solutions for the spectral Green's functions of the cylinder as well

Saliva and serum samples were collected
Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26-hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20-40 pg/ml. All subjects had low levels (P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high-secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low-secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood.
✍ Maija-Liisa Laakso; Tarja Porkka-Heiskanen; Aino Alila; Dag Stenberg; Gunnar Joh πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 622 KB