✦ Synopsis


Abstract

Images reconstructed from multielement, phased array coils and presented as the square root of the sum of the squares of the signals received by the individual elements have a distribution of signal and noise that distorts the relationship between the image intensity and the underlying signal. The distortion is accentuated for long echo times for which the signal‐to‐noise ratio (SNR) may be low. When measuring T~2~ or T this signal distortion leads to biased estimates of these parameters. We demonstrate this effect and its dependence on the image SNR and the number of elements in a phased array coil. We evaluated the effects of four techniques for calculating T~2~ from data acquired in phased array coils (log transform, least squares, lookup table correction, and maximum likelihood [ML] estimation). The ML estimation gave the most accurate T~2~ in the presence of this bias. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Improvements in carotid plaque imaging u
✍ Niranjan Balu; Vasily L. Yarnykh; Joshua Scholnick; Baocheng Chu; Chun Yuan; Cec 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 392 KB

## Abstract ## Purpose To design and compare an eight‐channel phased array (PA) coil for carotid imaging to an established four‐channel PA design at 3T. ## Materials and Methods An eight‐channel PA (8PA) coil was designed specifically for imaging the carotid bifurcation and compared with the exi

Comparison of a 28-channel receive array
✍ Gregory Chang; Graham C. Wiggins; Ding Xia; Riccardo Lattanzi; Guillaume Madelin 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 835 KB

## Abstract ## Purpose: To compare a new birdcage‐transmit, 28‐channel receive array (28‐Ch) coil and a quadrature volume coil for 7T morphologic MRI and T2 mapping of knee cartilage. ## Materials and Methods: The right knees of 10 healthy subjects were imaged on a 7T whole body magnetic resonan

The value of respiratory triggered T2-we
✍ Tomohiro Namimoto; Yasuyuki Yamashita; Katsuhiko Mitsuzaki; Mutsumasa Takahashi 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 921 KB

## Abstract The purpose of this study was to evaluate the value of the respiratory triggered turbo spin‐echo (TSE) technique for T2‐weighted MRI of liver lesions. Fifty‐nine patients (32 men, 27 women; mean age, 63.3 years) with focal hepatic lesions were prospectively studied with MRI at 1.5 T wit