𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil

✍ Scribed by Tomohiro Namimoto; Yasuyuki Yamashita; Katsuhiko Mitsuzaki; Mutsumasa Takahashi


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
921 KB
Volume
8
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The purpose of this study was to evaluate the value of the respiratory triggered turbo spin‐echo (TSE) technique for T2‐weighted MRI of liver lesions. Fifty‐nine patients (32 men, 27 women; mean age, 63.3 years) with focal hepatic lesions were prospectively studied with MRI at 1.5 T with use of a body phased array coil. In the first 15 patients, breath‐hold TSE, respiratory triggered TSE, and conventional nonrespiratory triggered TSE T2‐weighted imaging were compared. Because nonrespiratory triggered TSE imaging was significantly inferior (P < .01) to breath‐hold or respiratory triggered images, breath‐hold and respiratory triggered TSE T2‐weighted images were compared in the remaining 44 patients. Images were analyzed quantitatively by measuring the liver signal‐to‐noise ratio and the lesion‐liver and spleen‐liver contrast‐to‐noise ratios and qualitatively by evaluating the lesion conspicuity, liver parenchymal homogeneity, and sharpness of intrahepatic vessels. The imaging time was 26 seconds for breath‐hold TSE imaging, 49 to 219 seconds (mean, 149 seconds) for the respiratory triggered TSE imaging, and 79 to 379 seconds (mean, 239 seconds) for the nonrespiratory triggered TSE imaging. Quantitatively, the signal‐to‐noise ratio of the liver for breath‐hold imaging was comparable to that for respiratory triggered imaging. The lesion‐liver and liver‐spleen contrast‐to‐noise ratios for the respiratory triggered images were greater by 37% and 39%, respectively, than for the breath‐hold T2‐weighted TSE images. Qualitatively, the respiratory triggered images showed lower frequency of image artifact, better lesion conspicuity, and greatly superior depiction of intrahepatic structures compared with the breath‐hold T2‐weighted TSE images. The respiratory triggered T2‐weighted TSE technique provides better quality liver images than the breath‐hold TSE technique or nonrespiratory triggered technique within a reasonable acquisition time.


📜 SIMILAR VOLUMES


T2-weighted MR imaging of the chest: Com
✍ John L. Haddad; Neil M. Rofsky; Michael M. Ambrosino; David P. Naidich; Jeffrey 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 604 KB

In 22 patients with a diverse range of thoracic abnormalities, T2-weighted magnetic resonance (MR) images of the chest were obtained with electrocardiograph (ECG)-triggered turbo spin-echo (TSE), ECG-triggered conventional spin-echo (CSE), and nontriggered TSE sequences, and the images were compared

Can a single-shot black-blood T2-weighte
✍ Shahid M. Hussain; Jan De Becker; Wim C.J. Hop; Soendersing Dwarkasing; Piotr A. 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 631 KB

## Abstract ## Purpose To optimize and assess the feasibility of a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging (SSBB‐EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2‐weighted turbo spin‐echo (TSE) seq

Magnetic resonance imaging of the upper
✍ Christian Klessen; Patrick Asbach; Thomas J. Kroencke; Thomas Fischer; Carsten W 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 342 KB

## Abstract ## Purpose To evaluate a free‐breathing navigator triggered T2‐weighted turbo spin‐echo sequence with prospective acquisition correction (T2w‐PACE‐TSE) for MRI of the upper abdomen in comparison to a conventional T2‐weighted TSE (T2w‐CTSE), a single‐shot TSE (T2w‐HASTE), and a T1‐weigh

Motion artifact in T2-weighted fast spin
✍ Kyuran A. Choe; Robert C. Smith; Ken Wilkens; R. Todd Constable 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 981 KB

## Abstract The purpose of our study was to evaluate the effect of respiratory motion on the image contrast of T2‐weighted fast spin‐echo (FSE) images of the liver as well as the reduction of motion artifact using respiratory triggering of the data acquisition. We imaged the livers of 10 healthy vo

Fat-suppressed T2-weighted MRI of the li
✍ Motoyuki Katayama; Takayuki Masui; Shigeru Kobayashi; Tatsuhiko Ito; Mamoru Taka 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 581 KB

## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with