Introduction: Previous studies demonstrated that multiple treatments using focused ultrasound can be effective as an non-invasive method for reducing unwanted localized fat deposits. The objective of the study is to investigate the safety and efficacy of this focused ultrasound device in body contou
Body contouring by non-invasive transdermal focused ultrasound
✍ Scribed by J. Moreno-Moraga; T. Valero-Altés; A. Martínez Riquelme; M.I. Isarria-Marcosy; J. Royo de la Torre
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 445 KB
- Volume
- 39
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Background and Objectives
The risks of currently available invasive procedures in body contouring motivate a need for safer, non‐invasive technologies for improving the appearance of body silhouette. A new device has been developed that uses focused therapeutic ultrasound to reduce adipose tissue non‐invasively. The aim of this study was to assess the efficacy and safety of a novel non‐invasive focused ultrasound system (UltraShape Ltd, Tel Aviv, Israel) in reducing localized fat deposits to improve body contours.
Study Design/Patients and Methods
A prospective study was conducted on 30 healthy patients. All patients underwent three treatments, at 1‐month intervals, and were followed for 1 month after the last treatment. Areas treated were the abdomen, inner and outer thighs, flanks, inner knees, and breasts (males only). No other body contouring procedure was used during the study. Efficacy was determined by change in fat thickness, assessed by ultrasound measurements, and by circumference measurements. Weight change was monitored to assess whether reduction in fat thickness or circumference was dependent on or independent of weight loss. Safety was determined by clinical findings, assays of serum triglycerides, and liver ultrasound evaluation for the presence of steatosis.
Results
All patients showed significant reduction in subcutaneous fat thickness within the treated area. The mean reduction in fat thickness after three treatments was 2.28±0.80 cm. Circumference was reduced by a mean of 3.95±1.99 cm. Weight was unchanged during the treatment and follow‐up period. No adverse effects were observed.
Conclusions
This study shows the efficacy and safety of focused ultrasound, using the UltraShape™ Contour I, as a non‐invasive transdermal method for reducing unwanted fat deposits in the body. Multiple treatments combined with appropriate patient and treatment area selection can produce dramatic improvements in body contour. Lasers Surg. Med. 39: 315–323, 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Background The objective of the study is to determine the clinical efficacy and patient satisfaction of a novel cryolipolysis device (Zeltiq®) for body contouring in Chinese after a single treatment and after 2 treatments at a commercial setting. ## Materials and Methods Two group
Background and Objectives: Transcutaneous intense focused ultrasound has emerged as a novel technology for non-invasive skin tightening. The objective of this study was to evaluate the safety profile of a transcutaneous focused ultrasound device for the treatment of facial skin laxity in Asians. Mat
## Background and objective: Transmission electron microscopic images have demonstrated the formation of transitory pores in adipocyte cell membranes followed by the collapse of adipose cells subsequent to laser irradiation of 635 nm. the objective is to evaluate the application of a 635 nm and 17.
Fresh canine whole blood was exposed in 1.3-mL disposable pipette bulbs with or without added Albunex contrast agent to lithotripter shock waves (rate: 2 Hz; mean pressure amplitude: 14.8 MPa) or 1.28-MHz high-intensity focused ultrasound up to a mean pressure amplitude of 17.8 MPa. Significant shoc