Background and Objectives: Transcutaneous intense focused ultrasound has emerged as a novel technology for non-invasive skin tightening. The objective of this study was to evaluate the safety profile of a transcutaneous focused ultrasound device for the treatment of facial skin laxity in Asians. Mat
The use of focused ultrasound for non-invasive body contouring in Asians
β Scribed by Sam Shek; Carol Yu; C.K. Yeung; Taro Kono; Henry H. Chan
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 491 KB
- Volume
- 41
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
β¦ Synopsis
Introduction: Previous studies demonstrated that multiple treatments using focused ultrasound can be effective as an non-invasive method for reducing unwanted localized fat deposits. The objective of the study is to investigate the safety and efficacy of this focused ultrasound device in body contouring in Asians. Method: Fifty-three (51 females and 2 males) patients were enrolled into the study. Subjects had up to three treatment sessions with approximately 1-month interval in between treatment. Efficacy was assessed by changes in abdominal circumference, ultrasound fat thickness, and caliper fat thickness. Weight change was monitored to distinguish weight loss induced changes in these measurements. Patient questionnaire was completed after each treatment. The level of pain or discomfort, improvement in body contour and overall satisfaction were graded with a score of 1-5 (1 being the least). Any adverse effects such as erythema, pain during treatment or blistering were recorded. Result: The overall satisfaction amongst subjects was poor. Objective measurements by ultrasound, abdominal circumference, and caliper did not show significant difference after treatment. There is a negative correlation between the abdominal fat thickness and number of shots per treatment session. Conclusion: Focused ultrasound is not effective for noninvasive body contouring among Southern Asians as compared with Caucasian. Such observation is likely due to smaller body figures. Design modifications can overcome this problem and in doing so, improve clinical outcome.
π SIMILAR VOLUMES
The prenatal determination of fetal lung maturity is currently assessed by chemical analysis of surfactant associated lipids from amniotic fluid obtained by amniocentesis. This is an invasive procedure with rare but occasionally serious morbidity. Magnetic resonance spectroscopy (MRS) is a non-invas
The proteome of the yeast Saccharomyces cerevisiae was analysed by two-dimensional (2D) polyacrylamide gel electrophoresis utilizing a non-linear immobilized pH gradient (3-10) in the first-dimensional separation. Cells were labelled by [ 35 S]methionine incorporation in the respiro-fermentative pha