## Abstract This study reports a high‐resolution MRI approach to image basal blood flow and hypercapnia‐induced blood‐flow changes in the unanesthetized human retina on a 3‐T MRI scanner. Pseudocontinuous arterial spin labeling technique with static tissue suppression was implemented to minimize mo
Blood flow quantification of the human retina with MRI
✍ Scribed by Nasim Maleki; Weiying Dai; David C. Alsop
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 238 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0952-3480
- DOI
- 10.1002/nbm.1564
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The purpose of this study was to investigate the feasibility of measuring blood flow to the retina using arterial spin labeling MRI, a quantitative, noninvasive tomographic technique. Blood flow imaging was performed in a single axial slice through both eyes of five healthy volunteers with no history of retinal diseases. The imaging was optimized to minimize the errors from motion and nonuniform magnetic fields caused by proximity to the sinuses. Key hemodynamic factors for flow quantification, including arterial transit delay and the apparent decay time of the signal, were estimated by repeated measurements with different arterial spin labeling timing. A clearly elevated signal, consistent with the anatomical location of the retina, was observed in all subjects. The measured blood flow to a 1 cm × 1.47 cm section of the retina, centered on the fovea, was 1.75 ± 0.54 µL/mm^2^/min (total blood flow of 261 ± 87 µL/min). The arterial transit delay from a labeling plane 5 cm below the slice was 1137 ± 288 ms. These results establish the feasibility of measuring blood flow to the retina with MRI, and support the future characterization of the healthy and diseased ocular circulation with this method. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract Dynamic susceptibility contrast MRI (DSC‐MRI) is the current standard for the measurement of Cerebral Blood Flow (CBF) and Cerebral Blood Volume (CBV), but it is not suitable for the measurement of Extraction Flow (EF) and may not allow for absolute quantification. The objective of this
## Abstract The goal of this study was to demonstrate high‐resolution anatomical, blood oxygenation level‐dependent, and blood flow MRI on large nonhuman primate retinas using a 3‐Tesla clinical scanner as a first step toward translation. Baboon was chosen because of its evolutionary similarity to
## Abstract Regional cerebral arterial blood volume (CBVa) and blood flow (CBF) can be quantitatively measured by modulation of tissue and vessel (MOTIVE) signals, enabling separation of tissue signal from blood. Tissue signal is selectively modulated using magnetization transfer (MT) effects. Bloo