𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Anatomical, blood oxygenation level-dependent, and blood flow MRI of nonhuman primate (baboon) retina

✍ Scribed by Yi Zhang; Hsiao-Ying Wey; Oscar San Emeterio Nateras; Qi Peng; Bryan H. De La Garza; Timothy Q. Duong


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
414 KB
Volume
66
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The goal of this study was to demonstrate high‐resolution anatomical, blood oxygenation level‐dependent, and blood flow MRI on large nonhuman primate retinas using a 3‐Tesla clinical scanner as a first step toward translation. Baboon was chosen because of its evolutionary similarity to human. Anesthetized preparation, free of eye‐movement artifacts, was used to evaluate clinical scanner hardware feasibility and optimize multimodal protocols for retinal MRI. Anatomical MRI (0.1 × 0.2 × 2.0 mm^3^) before contrast‐agent injection detected three alternating bright–dark–bright layers. The hyperintense inner strip nearest to the vitreous was enhanced by an intravascular contrast agent, which likely included the ganglion and bipolar cell layer and the embedded retinal vessels. The hypointense middle strip showed no contrast enhancement, which likely included the avascular outer unclear layer and photoreceptor segments. The hyperintense outer strip showed contrast enhancement, which likely corresponded to the choroid vascular layer. In the posterior retina, the total thickness including the choroid was 617 ± 101 μm (± standard deviation, n = 7). Blood oxygenation level‐dependent functional MRI (0.3 × 0.6 × 2.0 mm^3^) of oxygen inhalation relative to air increased the signals by 6.5 ± 1.4%. Basal blood flow (2 × 2 × 2 mm^3^) was 83 ± 30 mL/100 g/min (air), and hypercapnia increased blood flow by 25 ± 9% (P < 0.05). This study demonstrates multimodal MRI to image anatomy, physiology, and function on large nonhuman primate retinas using a clinical scanner, offering encouraging data to explore human applications. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Blood oxygenation level-dependent MRI of
✍ Yuan-Yu Hsu; Chen-Nen Chang; Shih-Ming Jung; Kun-Eng Lim; Ju-Chuan Huang; Shin-Y 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 484 KB

## Abstract ## Purpose To assess the cerebrovascular responses to short breath holding of cerebral gliomas using blood oxygenation level‐dependent (BOLD) magnetic resonance imaging (MRI). ## Materials and Methods Six patients with a low‐grade glioma and one patient with a high‐grade glioma were

Comparison of 1H blood oxygen level–depe
✍ Dawen Zhao; Lan Jiang; Eric W. Hahn; Ralph P. Mason 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 408 KB

## Abstract Fluorine‐19 [^19^F] MRI oximetry and ^1^H blood oxygen level–dependent (BOLD) MRI were used to investigate tumor oxygenation in rat breast 13762NF carcinomas, and correlations between the techniques were examined. A range of tissue oxygen partial pressure (pO~2~) values was found in the

Effects of aging on cerebral blood flow,
✍ Beau M. Ances; Christine L. Liang; Oleg Leontiev; Joanna E. Perthen; Adam S. Fle 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 493 KB

## Abstract Calibrated functional magnetic resonance imaging (fMRI) provides a noninvasive technique to assess functional metabolic changes associated with normal aging. We simultaneously measured both the magnitude of the blood oxygenation level dependent (BOLD) and cerebral blood flow (CBF) respo

Functional imaging of the parotid glands
✍ Sonia C. Simon-Zoula; Chris Boesch; Frederik De Keyzer; Harriet C. Thoeny 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 173 KB

## Abstract ## Purpose To evaluate the function of the parotid glands before and during gustatory stimulation, using an intrinsic susceptibility‐weighted MRI method (blood oxygenation level dependent, BOLD‐MRI) at 1.5T and 3T. ## Materials and Methods A total of 10 and 13 volunteers were investi

Blood-oxygen level dependent MRI measure
✍ Andrea Kassner; Jeff D. Winter; Julien Poublanc; David J. Mikulis; Adrian P. Cra 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 212 KB

## Abstract ## Purpose: To evaluate the reproducibility and gender differences in cerebrovascular reactivity (CVR) measurements obtained using the blood‐oxygen level dependent (BOLD) response to controlled changes in end‐tidal partial pressure of carbon dioxide (PETCO~2~). ## Materials and Method