✦ Synopsis


The biomechanics of the hip joint provide an understanding of the development, evolution, and treatment of many disabling conditions of this joint. The available methods of biomechanical analysis include in vitro studies, in vivo studies, and theoretical mathematic analyses. The information obtained from these analyses have enabled the design of therapeutic programs to alleviate the symptoms of, and possibly delay the progression of, hip disease. The design of surgical procedures has been based on alterations of the biomechanics of the hip. These procedures have proven useful for treating pathologies such as osteoarthritis, hip dysplasia, and hip fractures. The study of biomechanics and biomaterials are integral to the current success of total hip arthroplasty in achieving pain relief and functional


πŸ“œ SIMILAR VOLUMES


Polyethylene wear in total hip and knee
✍ Lewis, Gladius πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 272 KB πŸ‘ 1 views

The role that ultrahigh molecular weight polyethylene (UHMWPE) wear at bearing surfaces in total hip and knee arthroplasties plays in the clinical life of these implants cannot be overemphasized. This subject has therefore been attracting enormous research attention on both fundamental and technolog

Lymphocyte responses in patients with to
✍ Nadim James Hallab; Shelley Anderson; Tiffany Stafford; Tibor Glant; Joshua J. J πŸ“‚ Article πŸ“… 2005 πŸ› Elsevier Science 🌐 English βš– 1023 KB

## Abstract How lymphocyte‐mediated metal sensitivity affects orthopaedic implant performance remains poorly understood. Do patients with implants exhibit elevated lymphocyte reactivity to metals and is this reactivity more generalized or more implant‐alloy specific? We investigated these questions

Testing of silicon nitride ceramic beari
✍ B. Sonny Bal; Ashok Khandkar; R. Lakshminarayanan; Ian Clarke; Aaron A. Hoffman; πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 415 KB

## Abstract Modern ceramic bearings used in total hip arthroplasty (THA) consist of a femoral head (ball) articulating inside a hemispherical acetabular cup (socket); the ball and socket are made of alumina (Al~2~O~3~) and Al~2~O~3~‐based composite materials. In the present study, total hip bearing