✦ Synopsis


The analysis of hormones in saliva is a powerful tool in the assessment of a patient's endocrine function, since it allows multiple noninvasive samplings. Since salivary levels of most hormones are 10 to 50 times lower than plasma levels, accurate and highly sensitive assays are needed for saliva measurements. Herein, we describe the development of a solid-phase competitive immunoassay for cortisol in saliva, in which a mutant of the photoprotein aequorin has been used as a label. We have chemically conjugated cortisol to aequorin at different molar ratios. The various cortisol-aequorin conjugates were characterized in terms of bioluminescent activity and affinity for the anti-cortisol antibody. The conjugate that gave the best analytical performance was used for the development of the immunoassay and the analysis of cortisol in saliva samples. The conjugates were stable for at least 6 months when stored at 4 degrees C. The method fulfilled all the standard requirements of precision and accuracy. The optimized immunoassay gave a detection limit of 300 fmol/tube, corresponding to 3 nmol/L, with a linear dynamic range of 10-1000 nmol/L. Therefore, cortisol can be detected down to 0.1 ng in 100 microl of saliva sample using this assay, without any sample pretreatment. This detection limit is almost one order of magnitude lower than the physiological levels of salivary cortisol, which are reported to be 10-25 nmol/L. This allows the quantification of salivary cortisol to be performed in the linear range of the calibration curve, which is most reliable for quantification purposes.


📜 SIMILAR VOLUMES


Bioluminescent enzyme immunoassay for es
✍ Fredrick S. Yein; Charles K. Marschke; Philip C. Deming; Thomas F. Holzman; Paul 📂 Article 📅 1985 🏛 Elsevier Science 🌐 English ⚖ 562 KB

A bioluminescent enzyme immunoassay using estriol labeled with reversibly inactivated bacterial luciferase is described. An estriol derivative bearing an alkylthiolsulfonate is linked to the cysteinyl thiols of Iuciferase by formation of mixed disuhide linkages; thus, luciferase becomes inactive. Af

Chemiluminescent enzyme immunoassay for
✍ Arakawa, H. ;Ikegami, T. ;Maeda, M. ;Tsuji, A. 📂 Article 📅 1993 🏛 John Wiley and Sons ⚖ 296 KB

## Abstract We developed a sensitive chemiluminescent sandwich‐type enzyme immunoassay (CLEIA) of alpha‐fetoprotein (AFP) using b̃‐D‐galactosidase (b̃‐gal) as a label and 5‐bromo‐4‐chloro‐3‐indolyl‐b̃‐D‐galactopyranoside as a substrate. The CL‐EIA for AFP was performed using two monoclonal antibodi