## Abstract Ideally, implants should inhibit nonspecific protein adsorption, bacterial adhesion, and at the same time, depending on the final application be selective toward cellular adhesion and spreading for all or only selected cell types. Poly(L‐lysine)‐__grafted__‐poly(ethylene glycol) (PLL‐__
Bacteria and cell cytocompatibility studies on coated medical grade titanium surfaces
✍ Scribed by L. G. Harris; L. Mead; E. Müller-Oberländer; R. G. Richards
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 403 KB
- Volume
- 78A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Acute and chronic osteomyelitis caused by staphylococci can be difficult to treat by conventional means and often has marked consequences for the patient. Current methods of treatment involve the use of systemic antibiotics, the local implantation of nondegradable drug carriers, and surgical debridement. A possible solution that could prevent initial bacterial adhesion could be to modify the implant surface with an antimicrobial coating while maintaining biocompatibility to host cells. This study describes the cytocompatibility evaluation of different coatings (poly(D,L‐lactide) (PDLLA), politerefate (PTF), calcium phosphate/anodic plasma‐chemical treatment (CaP/APC), polyurethane (PU), and polyvinylpyrollidone (PVP) on titanium surfaces with and without chlorhexidine diacetate (CHA) to Staphylococcus aureus, Staphylococcus epidermidis, and hTERT human fibroblasts. Surface characterization of the coatings showed no significant variation in the roughness or hydrophobicity of the coated surfaces, except the CaP/APC surface that was porous yet the smoothest, and PVP, PVP + CHA, and CaP/APC + CHA that were more hydrophilic in nature than the others. On the surfaces without CHA, both staphylococcal strains and spread fibroblasts were observed, but on the CHA impregnated surfaces few bacteria and no intact fibroblasts were seen. Flow cytometry found fewer bacteria in the media and on the surfaces containing CHA in comparison to the surfaces without CHA. The release kinetics varied from slow (over 200 h) to burst release: PDLLA > PTF > PU > CaP/APC = PVP. This study showed that PDLLA and PTF have the best potential as coatings on implants for drug delivery, as they were cytocompatible to hTERT fibroblasts, eluted CHA effectively, and passed mechanical testing. The actual release kinetics of PDLLA and PTF are important, as the amount of CHA present should remain above the minimal inhibitory concentration value for a limited time before disappearing completely. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
📜 SIMILAR VOLUMES
## Abstract Osteoconduction and osseointegration are the critical stages for implantation success. Peptides containing RGD (Arg‐Gly‐Asp) adhesive sequence are known to promote cell adhesion and consequently to favor osseointegration of medical devices. In this study, RGD peptides were coupled to a
## Abstract The aim of this study was to characterize and compare various titanium (Ti) and hydroxyapatite (HA) coatings on Ti6Al4V, in view of their application on noncemented orthopedic implants. Two innovative vacuum plasma sprayed (VPS) coatings, the first of ultrahigh rough and dense Ti (PG60,
## Abstract Roughened titanium (Ti) surfaces have been widely used for dental implants. In recent years, there has been the tendency to replace Ti plasma‐sprayed surfaces by sandblasted and acid‐etched surfaces in order to enhance osseous apposition. Another approach has been the utilization of hyd