## Abstract ## Purpose To improve dark‐blood and short tau inversion recovery (STIR) prepared turbo spin‐echo (TSE) imaging of the heart, particularly in the basal short‐axis plane where cardiac misregistration between the preparation and imaging phases is high. ## Materials and Methods In the f
Axial black blood turbo spin echo imaging of the right ventricle
✍ Scribed by Seth J. Berkowitz; Robson Macedo; Ashkan A. Malayeri; Steven M. Shea; Christine H. Lorenz; Hugh Calkins; Jens Vogel-Claussen; Harikrishna Tandri; David A. Bluemke
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 348 KB
- Volume
- 61
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Black blood turbo spin echo (TSE) imaging of the right ventricle (RV) free wall is highly sensitive to cardiac motion, frequently resulting in nondiagnostic images. Temporal and spatial parameters of a black blood TSE pulse sequence were evaluated for visualization of the RV free wall. Seventy‐four patient studies were retrospectively evaluated for the effects of acquisition timing on image quality. Axial black blood TSE images were acquired on 10 healthy volunteers to assess the role of spatial misregistration on right ventricle visualization; increasing the double inversion recovery (DIR) slice thickness beyond 300% had no effect on image quality (P = 0.2). Thirty‐five patient studies were prospectively evaluated with inversion times (TIs) corresponding to the mid‐diastolic rest period and end‐systole based on visual analysis of a four chamber cine. When TIs were chosen to be within the patients' RV rest period, mean image quality score was significantly improved (2.3 vs 1.86; P < 0.001) and the number of clinically diagnostic images increased from 32% to 46%. Black blood TSE imaging of the RV free wall is highly sensitive to cardiac motion. Image quality can be improved by choosing TIs concordant with the rest period of the patient's RV that may occur at mid‐diastole or end‐systole. Magn Reson Med 61:307–314, 2009. © 2009 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
In 22 patients with a diverse range of thoracic abnormalities, T2-weighted magnetic resonance (MR) images of the chest were obtained with electrocardiograph (ECG)-triggered turbo spin-echo (TSE), ECG-triggered conventional spin-echo (CSE), and nontriggered TSE sequences, and the images were compared
So that we might evaluate the ultrafast half-Fourier single-shot turbo spin-echo (HASTE) sequence in T2-weighted MRI of the female pelvis and compare it with the turbo spin-echo (TSE) sequence, we prospectively studied 60 consecutive females with suspected abnormalities of the pelvis. For all MR exa
## Abstract ## Purpose To optimize and assess the feasibility of a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging (SSBB‐EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2‐weighted turbo spin‐echo (TSE) seq
The conditions in which the image intensity of vessels transporting laminar flow is attenuated in black-blood MR angiography (BB-MRA) with turbo spin-echo (TSE) and conventional spinecho (CSE) pulse sequences are investigated experimentally with a flow phantom, studied theoretically by means of a Bl
## Abstract Magnetic resonance (MR) imaging with multi‐planar, gated Half‐Fourier Acquisition Single‐Shot Turbo Spin‐Echo (HASTE) imaging was performed to evaluate a woman with dysrhythmia. MR examination for right ventricular dysplasia revealed a Morgagni hernia. The HASTE images depicted well the