Automatic calibration and dilution in unsegmented flow systems

✍ Scribed by M. Agudo; A. Ríos; M. Valcárcel


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
627 KB
Volume
264
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


An open-closed flow system allowmg variable volumes of standard calibration solution to be introduced and automatlcally diluted was used to cany out automatic cahbratlons m unsegmented flow systems A ddutlon loop was thus established m which its final homogenized volume was used as diluted sample or cahbrant solution m the mam flow system The performance of the ddutlon loop was tested both m mlectlon and m completely continuous flow systems and was found to be appropriate for analytical process control


📜 SIMILAR VOLUMES


Automatic implementation of the method o
✍ Manuel Agudo; Angel Ríos; Miguel Valcárcel 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 583 KB

An open/closed flow system allowing variable volumes of both sample and standard calibration solution to be introduced was employed to perform automatic calibration in unsegmented flow systems by using the method of standard additions. The dilution loop thus established was used to homogenize the sa

Automatic titrations in unsegmented flow
✍ J. Marcos; A. Ríos; M. Valcárcel 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 643 KB

Vanable flow-rate patterns were used to develop automatic complexometrlc and redox tltratlon procedures m usegmented contmuous-flow systems Complexometrlc tltratlons were camed out by usmg EDTA as titrant and were apphed to single and simultaneous determmatlons of several metal Ions with coloured md

Automatic titrations in unsegmented flow
✍ J. Marcos; A. íos; M. Valcárcel 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 485 KB

Automatx acid-base trtratlons were carned out by generating pH grachents m a continuous-flow mamfold A programmable, computer-controlled pump was used to produce vanable, reproducible flow-rate patterns that were used to mcrease gradually the tltrant concentration m the flow system A colorlmetrlc md

Automatic calibration in capillary elect
✍ Lourdes Arce; Peter Hinsmann; Milko Novic; Angel Ríos; Miguel Valcárcel 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 183 KB 👁 1 views

A direct, completely automated calibration procedure in capillary electrophoresis (CE) is presented. The manual calibration operations involved in analytical methods, such as external calibration, standard addition, and internal standard, were accomplished with a continuous flow system (CFS) coupled