๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Automated gas chromatography/tandem mass spectrometry with on-line chemical derivatization for the determination of tebufelone and two metabolites in human plasma

โœ Scribed by Dobson, Roy L. M.; Dirr, Mary Kay; Merkt, Bonnie L.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
469 KB
Volume
32
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

โœฆ Synopsis


An automated capillary gas chromatography/tandem mass spectrometry (GC/MS/MS) assay for the simultaneous quantitation of tebufelone (TE) and its two major metabolites (PGE-1802413 and PGE-6285825) in plasma was developed. Using a 1:1 BSTFA:pyridine derivatization cocktail to solubilize plasma extracts, trimethylsilylation (TMS) of labile alcohol and carboxylic acid functional groups occurred instantly upon introducing each sample into a 300 degrees C GC injection port. This on-line chemical derivatization process rendered these three diverse analytes equally amenable to GC analysis and circumvented laborious off-line derivatization procedures. The selectivity of MS/MS conducted on a triple-quadrupole instrument allowed minimal sample preparation and rapid analysis. Electron ionization produced molecular ions (M.+) for TMS-TE, TMS2-PGE-1802413, TMS2-PGE-6285825 and their respective stable-isotope-labeled internal standards, which were selected in Q1 to undergo collisionally activated dissociation in Q2. Quantitation was achieved through monitoring product ions in Q3 at m/z 320, 445 and 305 for respective analytes, relative to corresponding internal standard ions at m/z 323, 449 and 305. A 2.5-1000 ng per sample (approximately 25 pg to 10 ng injected) quantitation range provided access to an effective 2.5-10,000 ppb plasma concentration range (0.1-1 ml samples) for each analyte. Based on quality control data accumulated throughout 8 months of method application, the assay showed no bias and composite (N = 212) relative standard deviations of 5.6%, 7.0% and 9.5% for the respective analytes (with quality control levels typically covering a range of 10-250 ng per analyte). During this period, more than 2000 plasma study samples were analyzed, attesting to the reliability and ruggedness of this approach for routine application.


๐Ÿ“œ SIMILAR VOLUMES


Fully automated determination of eserine
โœ Pruvost, A.; Ragueneau, I.; Ferry, A.; Jaillon, P.; Grognet, J.-M.; Benech, H. ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 109 KB ๐Ÿ‘ 2 views

A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for

An automated method for the simultaneous
โœ Kiyoshi Kawabata; Nobuko Matsushima; Kunihiro Sasahara ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 166 KB ๐Ÿ‘ 2 views

A new method for the determination of pravastatin, a potent inhibitor of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase, and its main metabolite (R-416) in human plasma using high-performance liquid chromatography/atmospheric pressure (negative ion) chemical ionization mass spectrometry (

High-performance liquid chromatography t
โœ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 88 KB ๐Ÿ‘ 2 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp

Column-switching High-performance Liquid
โœ Zell, M.; Husser, C.; Hopfgartner, G. ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 463 KB ๐Ÿ‘ 2 views

A liquid chromatographic/mass spectrometric (LC/MS) assay was developed for the simultaneous determination of a pro-drug (Ro 48-3657), its active metabolite (platelet inhibitor, Ro 44-3888) and precursor metabolite (Ro 48-3656) in human, dog and rat plasma, utilizing on-line column-switching solid-p