A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for
Automated gas chromatography/tandem mass spectrometry with on-line chemical derivatization for the determination of tebufelone and two metabolites in human plasma
โ Scribed by Dobson, Roy L. M.; Dirr, Mary Kay; Merkt, Bonnie L.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 469 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
โฆ Synopsis
An automated capillary gas chromatography/tandem mass spectrometry (GC/MS/MS) assay for the simultaneous quantitation of tebufelone (TE) and its two major metabolites (PGE-1802413 and PGE-6285825) in plasma was developed. Using a 1:1 BSTFA:pyridine derivatization cocktail to solubilize plasma extracts, trimethylsilylation (TMS) of labile alcohol and carboxylic acid functional groups occurred instantly upon introducing each sample into a 300 degrees C GC injection port. This on-line chemical derivatization process rendered these three diverse analytes equally amenable to GC analysis and circumvented laborious off-line derivatization procedures. The selectivity of MS/MS conducted on a triple-quadrupole instrument allowed minimal sample preparation and rapid analysis. Electron ionization produced molecular ions (M.+) for TMS-TE, TMS2-PGE-1802413, TMS2-PGE-6285825 and their respective stable-isotope-labeled internal standards, which were selected in Q1 to undergo collisionally activated dissociation in Q2. Quantitation was achieved through monitoring product ions in Q3 at m/z 320, 445 and 305 for respective analytes, relative to corresponding internal standard ions at m/z 323, 449 and 305. A 2.5-1000 ng per sample (approximately 25 pg to 10 ng injected) quantitation range provided access to an effective 2.5-10,000 ppb plasma concentration range (0.1-1 ml samples) for each analyte. Based on quality control data accumulated throughout 8 months of method application, the assay showed no bias and composite (N = 212) relative standard deviations of 5.6%, 7.0% and 9.5% for the respective analytes (with quality control levels typically covering a range of 10-250 ng per analyte). During this period, more than 2000 plasma study samples were analyzed, attesting to the reliability and ruggedness of this approach for routine application.
๐ SIMILAR VOLUMES
A new method for the determination of pravastatin, a potent inhibitor of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase, and its main metabolite (R-416) in human plasma using high-performance liquid chromatography/atmospheric pressure (negative ion) chemical ionization mass spectrometry (
A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp
A liquid chromatographic/mass spectrometric (LC/MS) assay was developed for the simultaneous determination of a pro-drug (Ro 48-3657), its active metabolite (platelet inhibitor, Ro 44-3888) and precursor metabolite (Ro 48-3656) in human, dog and rat plasma, utilizing on-line column-switching solid-p