We evaluated four newly introduced assays for determination of glycated hemoglobin allowing the processing of large amounts of samples in a clinical routine laboratory. These methods were compared to the Bio-Rad Diamat system.The investigated methods were the Merck Hitachi L-9100, a fully automated HPLC analyser, the Abbott IMx glycated hemoglobin ion capture assay, the DAKO HbA1 c enzyme linked immunosorbent assay (ELISA), and the Boehringer-Mannheim HbAlc Tinaquant turbidimetric assay. All methods showed generally acceptable precision and good accordance with the Diamat system. Interference study showed influence of anaemia, polycythemia, rheumatoid factor, and chronic hemodialysis on the values of the DAKO ELISA and of anaemia and polycythemia on the values of the Boehringer-Mannheim Tinaquant assay. All of the investigated methods allow referring of results either as measured or standardised HbAlc values, the latter obtained after calibration with reference to an ion exchange high-pressure liquid chromatography method. Our data confirm the feasibility of this kind of standardisation of glycated hemoglobin assays, allowing direct comparison of results from various determination methods.
๐ SIMILAR VOLUMES
## Abstract The PROCLEIXยฎ West Nile virus assay (WNV assay) is a qualitative nucleic acid test based on transcriptionโmediated amplification (TMA). The assay was used under an investigational protocol in the United States to screen blood donations for West Nile virus (WNV) RNA starting in the summe
## Abstract We evaluated a new analyzer (Cardio REP) specifically designed for cardiac CKโMB isoenzyme and isoforms activity, with a performance time of 24 minutes. Ten AMI patients, with times elapsed between the onset of chest pain and admission to hospital ranging from 30 minutes to 4 hours, wer
The potential teratogenic hazard of five compounds was evaluated using the Frog Embryo Teratogenesis Assay-Xenopus (FETAX) and a metabolic activation system. Embryos of the South African clawed frog, Xenopus laevis, were exposed to (i) three compounds suspected to be proteratogenic in mammalian test
Emergency toxicology or drug screening in clinical settings requires rapid qualitative and quantitative analysis with acceptable levels of sensitivity and specificity. The aim of this study was to comparatively evaluate the performance of the multi-column HPLCbased REMEDi drug profiling system (Bio-