๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Autocrosslinkable methyl-2-phenylethylpolysiloxane stationary phase for capillary column gas chromatography

โœ Scribed by Bradshaw, J. S. ;Crowley, S. J. ;Harper, C. W. ;Lee, M. L.


Publisher
John Wiley and Sons
Year
1984
Tongue
English
Weight
312 KB
Volume
7
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

โœฆ Synopsis


Methyl-2-phenylethylpolysiloxane polymers have been synthesized for comparison with methylphenylpolysiloxane stationary phases for gas chromatography. The 50% 2-phenylethyl polysiloxane was found to be autocrosslinkable at 26OOC without addition of free radical initiator. Although the selectivity of this phase appears to be similar to the 50% phenyl poiysiloxane, its thermal stability is not as high.


๐Ÿ“œ SIMILAR VOLUMES


4-(Methylsulfonyl)phenyl-containing poly
โœ Zoltan Juvancz; Michelle M. Schirmer; Deborah F. Johnson; Karin E. Markides; Jer ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 335 KB

## Abstract A new polar polysiloxane stationary phase for capillary column gas chromatography containing 4โ€(methylsulfonyl)phenyl substitution was synthesized and compared to a cyanophenylpolysiloxane, OVโ€225. The sulfonylphenylpolysiloxane phase was useful and stable over a wide temperature range

Effect of viscosity on stationary phase
โœ Wright, B. W. ;Peaden, P. A. ;Lee, M. L. ๐Ÿ“‚ Article ๐Ÿ“… 1982 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 355 KB ๐Ÿ‘ 1 views

## Abstract With recent advances in column technology it is now possible to prepare highly efficient, very inert, and thermally stable capillary columns coated with nonpolar polysiloxane stationary phases. Unfortunately, the same degree of success has not been achieved for some of the more polar po

Evaluation of smectic biphenylcarboxylat
โœ Markides, K. E. ;Chang, H-C. ;Schregenberger, C. M. ;Tarbet, B. J. ;Bradshaw, J. ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 366 KB

Mesomorphic biphenylcarboxylate esters were coupled via flexible aliphatic hydrocarbon spacers to a polysiloxane backbone. The influence of spacer length, percent mesomorphic substitution, and crosslinking of the stationary phase on liquidcrystalline transition temperatures and on chromatographic pe

Open crown ether polysiloxane stationary
โœ Lin-Shuang Cai; Cai-Ying Wu; Hui-Ming Han ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 479 KB

## Abstract In this paper, two new open crown ether polysiloxane stationary phases were prepared for capillary gas chromatography. Chromatographic characteristics, including column efficiency, operational temperature range, thermal stability, and polarity were studied. The open crown ether polysilo