๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

4-(Methylsulfonyl)phenyl-containing polysiloxane stationary phase for capillary column gas chromatography

โœ Scribed by Zoltan Juvancz; Michelle M. Schirmer; Deborah F. Johnson; Karin E. Markides; Jerald S. Bradshaw; Milton L. Lee


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
335 KB
Volume
3
Category
Article
ISSN
1040-7685

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

A new polar polysiloxane stationary phase for capillary column gas chromatography containing 4โ€(methylsulfonyl)phenyl substitution was synthesized and compared to a cyanophenylpolysiloxane, OVโ€225. The sulfonylphenylpolysiloxane phase was useful and stable over a wide temperature range from 70ยฐC to 320ยฐC, and it exhibited similar overall polarity to OVโ€225. However, because of the specific chemical properties of the 4โ€(methylsulfonyl)phenyl group, this phase demonstrated unique selectivities for certain classes of compounds including basic nitrogen heterocycles and polychlorinated biphenyls.


๐Ÿ“œ SIMILAR VOLUMES


Open crown ether polysiloxane stationary
โœ Lin-Shuang Cai; Cai-Ying Wu; Hui-Ming Han ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 479 KB

## Abstract In this paper, two new open crown ether polysiloxane stationary phases were prepared for capillary gas chromatography. Chromatographic characteristics, including column efficiency, operational temperature range, thermal stability, and polarity were studied. The open crown ether polysilo

Evaluation of smectic biphenylcarboxylat
โœ Markides, K. E. ;Chang, H-C. ;Schregenberger, C. M. ;Tarbet, B. J. ;Bradshaw, J. ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 366 KB

Mesomorphic biphenylcarboxylate esters were coupled via flexible aliphatic hydrocarbon spacers to a polysiloxane backbone. The influence of spacer length, percent mesomorphic substitution, and crosslinking of the stationary phase on liquidcrystalline transition temperatures and on chromatographic pe

Ionic liquid-bonded polysiloxane as stat
โœ Xiaojie Sun; Caiying Wu; Jun Xing ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 275 KB ๐Ÿ‘ 1 views

## Abstract Ionic liquid (IL) stationary phase is especially suitable for separation of complex samples, owing to the โ€œdual natureโ€ of IL. In this study, a synthetic method of ionic liquidโ€bonded polysiloxane (PSOIL) as stationary phase of GC was proposed. Then, the PSOIL was used to prepare an 8โ€‰m

Autocrosslinkable methyl-2-phenylethylpo
โœ Bradshaw, J. S. ;Crowley, S. J. ;Harper, C. W. ;Lee, M. L. ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 312 KB

Methyl-2-phenylethylpolysiloxane polymers have been synthesized for comparison with methylphenylpolysiloxane stationary phases for gas chromatography. The 50% 2-phenylethyl polysiloxane was found to be autocrosslinkable at 26OOC without addition of free radical initiator. Although the selectivity of

Crown ether substituted polysiloxanes as
โœ Jilong Ge; Ruonong Fu; Aiqin Zhang; Rongping Zhu; Jinghui Deng; Junling Gu; Jiya ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 373 KB

## Abstract Two new crown ether substituted polysiloxanes, 4โ€propylbenzoโ€15โ€crownโ€5polysiloxane(PSOโ€Bโ€15C5) and propyloxydibenzoโ€14โ€crownโ€4polysiloxane (PSOโ€DBโ€14C4), were prepared and used as stationary phases coated on fusedโ€silica open tubular columns. The chromatographic characteristics, includ