At-column injector for capillary GC — design and evaluation

✍ Scribed by Hagman, Gunnar ;Roeraade, Johan


Publisher
John Wiley and Sons
Year
1990
Tongue
English
Weight
392 KB
Volume
13
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The present paper describes constructional details and evaluations of an at‐column injector for capillary GC. Injections were made via a sample loop on a 0.32 mm i.d. capillary column. Two rotary valves were employed to allow a wash of the sample loop and a backflush of the transfer line. Repeatability, calculated from absolute area counts for n‐alkanes was between 0.3–1% RSD, for injected sample volumes between 5 and 100 μl. Promising results were also obtained with syringe‐based injections on narrow bore (100 μ i.d.) columns. Repeatability on the basis of normalized area counts was in the order of 0.1–0.2% RSD, while solvent tailing was practically absent.


📜 SIMILAR VOLUMES


Advances in the preparation and evaluati
✍ Verzele, M. ;Sandra, P. 📂 Article 📅 1979 🏛 John Wiley and Sons 🌐 English ⚖ 718 KB

## Abstract The preparation of (glass) capillary columns of high quality is still not without difficulties. Six problems in this context are highlighted. Column material choice(l), glass wall modification(2) and coating(3) are considered to have reached a satisfactory level. Deactivation(4) is stil

Potential and limitations of differently
✍ Staniewski, Jacek ;Rijks, Jacques A. 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 617 KB

## Abstract Programmed temperature sample introduction is an attractive technique both for the introduction of large volumes of dilute samples in capillary gas chromatography and for LC‐GC interfacing. In this study a new type of liner containing a porous bed of sintered glass is introduced and ev

Capillary GC column performance test for
✍ R. J. M. N. Dresen; H. J. W. Henderickx; Sj. Van Der Wal 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 210 KB

The traditional ''Grob test'' to assess the quality of capillary columns failed when testing base-deactivated columns. The methyl esters used as reference compounds in this test are partially lost on these columns. Furthermore, the two alkanes used are poorly soluble in polar solvents. Therefore, th

Automated at-column injection into narro
✍ Hagman, Gunnar ;Roeraade, Johan 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 283 KB

## Abstract An injector designed for automatic direct liquid injection into narrow bore capillary GC columns has been constructed and evaluated. The tip of the syringe needle is aligned with, and positioned close to, the column entrance in a small, pressurized cavity: when the sample is dispensed i