𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of liver viscoelasticity using multifrequency MR elastography

✍ Scribed by Patrick Asbach; Dieter Klatt; Uwe Hamhaber; Jürgen Braun; Rajan Somasundaram; Bernd Hamm; Ingolf Sack


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
703 KB
Volume
60
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

MR elastography (MRE) allows the noninvasive assessment of the viscoelastic properties of human organs based on the organ response to oscillatory shear stress. Shear waves of a given frequency are mechanically introduced and the propagation is imaged by applying motion‐sensitive gradients. An experiment was set up that introduces multifrequency shear waves combined with broadband motion sensitization to extend the dynamic range of MRE from one given frequency to, in this study, four different frequencies. With this approach, multiple wave images corresponding to the four driving frequencies are simultaneously acquired and can be evaluated with regard to the dispersion of the complex modulus over the respective frequency. A viscoelastic model based on two shear moduli and one viscosity parameter was used to reproduce the experimental wave speed and wave damping dispersion. The technique was applied in eight healthy volunteers and eight patients with biopsy‐proven high‐grade liver fibrosis (grade 3–4). Fibrotic liver had a significantly higher (P < 0.01) viscosity (14.4 ± 6.6 Pa · s) and elastic moduli (2.91 ± 0.84 kPa; 4.83 ± 1.77 kPa) than the viscosity (7.3 ± 2.3 Pa · s) and elastic moduli (1.16 ± 0.28 kPa; 1.97 ± 0.30 kPa) of normal volunteers. Multifrequency MRE is well suited for the noninvasive differentiation of normal and fibrotic liver as it allows the measurement of rheologic material properties. Magn Reson Med 60:373–379, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Assessment of thermal tissue ablation wi
✍ Tao Wu; Joel P. Felmlee; James F. Greenleaf; Stephen J. Riederer; Richard L. Ehm 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 288 KB

An important part of thermal ablation therapy is the assessment of the spatial extent of tissue coagulation. In this work, the mechanical properties of thermally-ablated tissue were quantitatively evaluated using magnetic resonance elastography (MRE). This study shows that the mechanical properties

Test–retest repeatability of MR elastogr
✍ Norah J. Shire; Meng Yin; Jun Chen; Radha A. Railkar; Sabrina Fox-Bosetti; Steph 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 419 KB 👁 2 views

## Abstract ## Purpose: To conduct a rigorous evaluation of the repeatability of liver stiffness assessed by MR elastography (MRE) in healthy and hepatitis‐C‐infected subjects. ## Materials and Methods: A biopsy‐correlated repeatability study using four‐slice MRE was conducted in five healthy an

Non-invasive measurement of brain viscoe
✍ Ingolf Sack; Bernd Beierbach; Uwe Hamhaber; Dieter Klatt; Jürgen Braun 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 214 KB

## Abstract The purpose of this work was to develop magnetic resonance elastography (MRE) for the fast and reproducible measurement of spatially averaged viscoelastic constants of living human brain. The technique was based on a phase‐sensitive echo planar imaging acquisition. Motion encoding was o

Hepatic viscoelastic parameters measured
✍ Najat Salameh; Frank Peeters; Ralph Sinkus; Jorge Abarca-Quinones; Laurence Anne 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 587 KB

## Abstract ## Purpose To determine the correlations between the viscoelastic parameters of the liver measured with in vivo MR elastography and quantitative analysis of liver fibrosis. ## Materials and Methods MR elastography of the liver was performed in 10 rats with hepatic fibrosis induced by