𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessing infection risk in implanted tissue-engineered devices

✍ Scribed by Roel Kuijer; Edwin J.P. Jansen; Pieter J. Emans; Sjoerd K. Bulstra; Jens Riesle; Jeroen Pieper; David W. Grainger; Henk J. Busscher


Publisher
Elsevier Science
Year
2007
Tongue
English
Weight
615 KB
Volume
28
Category
Article
ISSN
0142-9612

No coin nor oath required. For personal study only.

✦ Synopsis


Peri-operative contamination is the major cause of biomaterial-associated infections, highly complicating surgical patient outcomes. While this risk in traditional implanted biomaterials is well-recognised, newer cell-seeded, biologically conducive tissue-engineered (TE) constructs now targeted for human use have not been assessed for this possibility. We investigated infection incidence of implanted, degradable polyester TE scaffold biomaterials in rabbit knee osteochondral defects. Sterile, polyester copolymer scaffolds of different compositions and cell-accessible pore volumes were surgically inserted into rabbit osteochondral defects for periods of 3 weeks up to 9 months, either with or without initial seeding with autologous or allogeneic chondrocytes. Infection assessment included observation of pus or abscesses in or near the knee joint and post-mortem histological evaluation. Of 228 implanted TE scaffolds, 10 appeared to be infected: 6 scaffolds without cell seeding (3.6%) and 4 cell-seeded scaffolds (6.3%). These infections were evident across all scaffold types, independent of polymer composition or available pore volume, and up to 9 months. We conclude that infections in TE implants pose a serious problem with incidences similar to current biomaterials-associated infections. Infection control measures should be developed in tissue engineering to avoid further complications when TE devices emerge clinically.


πŸ“œ SIMILAR VOLUMES


Assessing peri-implant tissue infection
✍ Emily L. Perry; J. Peter Beck; Dustin L. Williams; Roy D. Bloebaum πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 368 KB

## Abstract __Background:__ Infection remains the main challenge to percutaneous, intramedullary osseointegrated implant technology. The purpose of this investigation was to determine if a broad spectrum antimicrobial, Cerageninβ„’ (CSA‐13) could prevent pin track infections in a percutaneous tibial

3-Tesla magnetic resonance angiographic
✍ Masashi Yamanami; Akihide Yamamoto; Hidehiro Iida; Taiji Watanabe; Keiichi Kanda πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 299 KB

## Abstract In the development of small‐caliber vascular grafts (diameter; less than 3 mm), animal implantation studies have been mostly performed by using rat abdominal aortas, and their certain patency must evaluate with sacrificing every observation periods, which is both labor‐intensive and tim

Development of a new percutaneous access
✍ Jansen, J. A. ;van der Waerden, J. P. C. M. ;de Groot, K. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 817 KB

The objective of this study was to evaluate a new type of percutaneous device (PD) designed to be implanted in soft tissues. The new PD consisted out of: (1) a flange-shaped subcutaneous component, made from sintered titanium fiber-web, and (2) a percutaneous component, made from dense sintered hydr