𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development of a new percutaneous access device for implantation in soft tissues

✍ Scribed by Jansen, J. A. ;van der Waerden, J. P. C. M. ;de Groot, K.


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
817 KB
Volume
25
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


The objective of this study was to evaluate a new type of percutaneous device (PD) designed to be implanted in soft tissues. The new PD consisted out of: (1) a flange-shaped subcutaneous component, made from sintered titanium fiber-web, and (2) a percutaneous component, made from dense sintered hydroxyapatite. The PDs were inserted in the back of 15 rabbits. The surgical procedure was performed in two steps. In the first session the subcutaneous component was placed.

In the second session, after 3-4 months the percutaneous component was fixed in the subcutaneous component. The implants were left ilz situ for 1 and 4 months after the second implantation session. Clinical and histological investigations were performed. It is found, that there was only a limited epidermal d o w ngrowth in the percutaneous area. No inflammatory reaction was observed in the dermal connective tissue. Histological analysis also demonstrated that titanium fiber mesh evokes minor adverse effects of the surrounding tissues. In conclusion, these experiments have shown that stabilization of the PD in the hypodermal area by using a sintered titanium fiber-web structure favors the longevity of PDs implanted in soft tissues.


πŸ“œ SIMILAR VOLUMES


A percutaneous implant using a porous me
✍ Fernie, G. R. ;Kostuik, J. P. ;Lobb, R. J. ;Pilliar, R. M. ;Wong, E. ;Binnington πŸ“‚ Article πŸ“… 1977 πŸ› John Wiley and Sons 🌐 English βš– 597 KB

## Abstract A percutaneous implant for the attachment of an artificial limb has been designed and tested in 14 pigs. Firm fixation to beone was achieved with the porous‐surface layered metal intramedullary stem design in some cases. Dacron velour was used at the soft tissue interface. Evidence of s

A new technique for quantitation of meta
✍ Dr. N. C. Blumenthal; V. Cosma; W. Jaffe; S. Stuchin πŸ“‚ Article πŸ“… 1994 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 312 KB

Tissue specimens retrieved from four regions adjacent to hip implants during revision surgery were subjected to a novel treatment to make possible the quantitative separation of residual metal particulates and metal reaction products (metal ions and metal-protein complexes). The tissues were exposed