With the successful launch of the first Earth Resources Technology Satellite (ERTS-1 or Landsat-1) on 23 July 1972, scientists and engineers gained a valuable new source of space-based observations for studying hydrologic systems and processes. Previously hampered by a lack of detailed spatial infor
Applications of integrated sensing and processing in spectroscopic imaging and sensing
β Scribed by Joseph Medendorp; Robert A. Lodder
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 270 KB
- Volume
- 19
- Category
- Article
- ISSN
- 0886-9383
- DOI
- 10.1002/cem.961
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Integrated sensing and processing (ISP) encompasses the use of optical computing and adapted excitation signals to physically implement chemometric calculations in spectroscopic sensors for imaging. As data sets become larger and more complex with each emerging generation of hyperspectral imagers, the βpixelβtoβpupilβ ratio increases at a rate faster than computing power can accommodate. In response to the need for faster and more efficient methods of processing, many analog solutions to the problem of high data dimensionality have emerged. The successful development of ISP has strong implications for military imaging, biosensing, spectroscopic imaging, and pharmaceutical process analytical technology (PAT). ISP developments in spectroscopy and PAT have emerged as alternatives to conventional Fourier transform infrared (FTβIR), nearβinfrared (NIR), IR, UVβvisible, fluorescence, Raman, and acousticβresonance spectrometry (ARS). Flourishing applications of ISP have demonstrated predictive ability equivalent to conventional approaches for sample differentiation and analyte quantification, in only a fraction of the time required for traditional spectrometric measurements. Copyright Β© 2006 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
This article summarizes theoretical and methodological advances in the study and application of a SOC, and serves as the introduction to a special issue devoted to this subject. Four themes emerged from the review. The first was that there continues to be a search for additional measures, despite th
## Abstract The purpose of this study was to evaluate the accuracy and reproducibility of phase contrast imaging using the sensitivity encoding (SENSE) method at different reduction factors. Analytical expressions were derived that state how reproducibility is influenced for velocity and flow measu
## Abstract Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enh