𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Application of ion chromatography with indirect spectrophotometric detection to the sensitive determination of alkylphosphonic acids and fosfomycin

✍ Scribed by G.A. Pianetti; L.M.Moreira de Campos; P. Chaminade; A. Baillet; D. Baylocq-Ferrier; G. Mahuzier


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
651 KB
Volume
284
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Indirect spectrophotometric detection was investigated for application in the anion-exchange chromatography of alkylphosphonic acids and fosfomycin. Four chromophoric eluent anions were studied: phthalate, benzoate, phenylphosphonate and p-toluenesulphonate. Phthalate showed the best displacing power and the larger dynamic reserve whereas benzoate exhibited the highest absorptivity and transfer ratio. The optimal experimental conditions were found to be 0.4 mM phthalate (pH 8.5) as mobile phase, a flow-rate of 1 ml min-1 and a detection wavelength of 272 nm. Selectivity (between 1.02 and 1.85, depending on the pair of vicinal compounds), linearity over a 5-100/zg m1-1 concentration range (r = 0.999), precision (R.S.D. 0.6-5.3%) and sensitivity (0.4-1.0/zg m1-1 according to the phosphonic acid) were determined. The minimum detectable concentrations were improved by an average factor of 50 in comparison with direct non-suppressed conductimetric detection. The application of the technique to the determination of fosfomycin in plasma samples is described.


πŸ“œ SIMILAR VOLUMES


Luminol Chemiluminescence with Heteropol
✍ Terufumi Fujiwara; Kiyomi Kurahashi; Takahiro Kumamaru; Hiroyuki Sakai πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 594 KB

A flow-injection chemiluminescence (CL) method has been proposed for sensitive determination of arsenate, germanate, phosphate and silicate, after separation by ion chromatography (IC). The post-column detection system involved formation of heteropoly acid in a H,SO, medium before the CL reaction wi

A sensitive determination of Ξ±-keto acid
✍ Shinji Ohmori; Yukari Tanaka; Mikiko Ikeda; Kazuhiro Hirota πŸ“‚ Article πŸ“… 1981 πŸ› Elsevier Science 🌐 English βš– 687 KB

A sensitive and selective determination of a-keto acids was established by the use of a gas chromatograph equipped with an electron capture detector. a-Keto acids (pyruvic, oxaloacetic, a-ketobutyric, and a-ketoglutaric acids) were reacted with pentafluorophenylhydrazine, and the derivatives were ex

Capillary electrophoresis with post-colu
✍ Milofsky, Robert ;Bauer, Eve πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 505 KB

## Abstract A detection scheme based on the Post‐column addition of terbium followed by sensitized luminescence detection has been developed. Two model Compounds‐ saliculic acid and diflunisa‐ were separated by capillary electophoresis in an alkaline phosphate buffer. A Solution containing terbium

Chemiluminescent derivatization of adeny
✍ Kuroda, Naotaka ;Nakashima, Kenichiro ;Akiyama, Shuzo ;Sato, Naofumi ;Imi, Norik πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons βš– 201 KB πŸ‘ 1 views

A chemiluminescence (CL) determination of adenyl compounds is described. CL derivatization of adenyl compounds with methylglyoxal dimethyl acetal was performed in the presence of tungstosilicic acid and propan-2-ol. CL from adenyl compounds was produced by hydrogen peroxide and L-cysteine ethyl este