## Dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection for the determination of N-methyl carbamate pesticides in vegetables This paper described a simple, rapid and efficient method for the determination of N-methyl carbamate pesticide
Application of dispersive liquid–liquid microextraction for the determination of phenylurea herbicides in water samples by HPLC-diode array detection
✍ Scribed by Mohammad Saraji; Neda Tansazan
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 323 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
A simple dispersive liquid-liquid microextraction method combined with HPLC-photodiode array detection has been developed for the determination of phenylurea herbicides in water samples. The herbicides studied included tebuthiuron, diuron, propanil, fluometuron, siduron, linuron, thidiazuron, and diflubenzuron. Several factors influencing the extraction efficiency of the studied compounds, such as extraction and disperser solvent type and their volumes, co-solvent type and its fraction, and ionic strength were investigated and optimized. Under the optimum extraction conditions, the calibration graphs were linear in the range of 0.2-200 mg/L for target analytes. The enrichment factors were between 11 and 118. The LOD were in the range of 0.01-0.5 mg/L (S/N 5 3). The relative standard deviations obtained ranged from 3.0 to 7.8% (n 5 5).
📜 SIMILAR VOLUMES
## Abstract In this paper, solid‐phase extraction (SPE) in combination with dispersive liquid–liquid microextraction (DLLME) has been developed as a sample pretreatment method with high enrichment factors for the sensitive determination of amide herbicides in water samples. In SPE–DLLME, amide herb
## Abstract A new method was developed for determination of methomyl in water samples by combining a dispersive liquid–liquid microextraction (DLLME) technique with HPLC–variable wavelength detection (VWD). In this extraction method, 0.50 mL of methanol (as dispersive solvent) containing 20.0 μL of
## Abstract This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norflox
## Abstract A novel dispersive liquid‐phase microextraction method without dispersive solvents has been developed for the enrichment and sensitive determination of triclosan and triclocarban in environmental water samples prior to HPLC‐ESI‐MS/MS. This method used only green solvent 1‐hexyl‐3‐methyl
## Abstract This paper describes a new method for rapid and sensitive determination of diflubenzuron, flufenoxuron, triflumuron and chlorfluazuron in water samples by ultrasound‐assisted ionic liquid dispersive liquid‐phase microextraction in combination with HPLC. Ionic liquid 1‐hexyl‐3‐methylimid