𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Application of dispersive liquid–liquid microextraction for the determination of phenylurea herbicides in water samples by HPLC-diode array detection

✍ Scribed by Mohammad Saraji; Neda Tansazan


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
323 KB
Volume
32
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


A simple dispersive liquid-liquid microextraction method combined with HPLC-photodiode array detection has been developed for the determination of phenylurea herbicides in water samples. The herbicides studied included tebuthiuron, diuron, propanil, fluometuron, siduron, linuron, thidiazuron, and diflubenzuron. Several factors influencing the extraction efficiency of the studied compounds, such as extraction and disperser solvent type and their volumes, co-solvent type and its fraction, and ionic strength were investigated and optimized. Under the optimum extraction conditions, the calibration graphs were linear in the range of 0.2-200 mg/L for target analytes. The enrichment factors were between 11 and 118. The LOD were in the range of 0.01-0.5 mg/L (S/N 5 3). The relative standard deviations obtained ranged from 3.0 to 7.8% (n 5 5).


📜 SIMILAR VOLUMES


Dispersive liquid–liquid microextraction
✍ Xiangyun Lin; Xiaohui Chen; Xin Huo; Zhiguo Yu; Kaishun Bi; Qing Li 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 193 KB

## Dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection for the determination of N-methyl carbamate pesticides in vegetables This paper described a simple, rapid and efficient method for the determination of N-methyl carbamate pesticide

Sensitive determination of amide herbici
✍ Ru-Song Zhao; Chun-Peng Diao; Qing-Feng Chen; Xia Wang 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 392 KB 👁 1 views

## Abstract In this paper, solid‐phase extraction (SPE) in combination with dispersive liquid–liquid microextraction (DLLME) has been developed as a sample pretreatment method with high enrichment factors for the sensitive determination of amide herbicides in water samples. In SPE–DLLME, amide herb

Application of dispersive liquid–liquid
✍ Guohui Wei; Yanyan Li; Xuedong Wang 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 280 KB

## Abstract A new method was developed for determination of methomyl in water samples by combining a dispersive liquid–liquid microextraction (DLLME) technique with HPLC–variable wavelength detection (VWD). In this extraction method, 0.50 mL of methanol (as dispersive solvent) containing 20.0 μL of

Development and optimization of the SPE
✍ Dragana Mutavdžić Pavlović; Sandra Babić; Davor Dolar; Danijela Ašperger; Krešim 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 431 KB

## Abstract This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norflox

Temperature-controlled ionic liquid disp
✍ Ru-Song Zhao; Xia Wang; Jing Sun; Jin-Peng Yuan; Shan-Shan Wang; Xi-Kui Wang 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 199 KB

## Abstract A novel dispersive liquid‐phase microextraction method without dispersive solvents has been developed for the enrichment and sensitive determination of triclosan and triclocarban in environmental water samples prior to HPLC‐ESI‐MS/MS. This method used only green solvent 1‐hexyl‐3‐methyl

Combination of ultrasound-assisted ionic
✍ Qingxiang Zhou; Xiaoguo Zhang 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 192 KB

## Abstract This paper describes a new method for rapid and sensitive determination of diflubenzuron, flufenoxuron, triflumuron and chlorfluazuron in water samples by ultrasound‐assisted ionic liquid dispersive liquid‐phase microextraction in combination with HPLC. Ionic liquid 1‐hexyl‐3‐methylimid