and glass-stoppered weighing bottles were found very convenient for the microscope slides. Plates took 30-50 min for development while slides required only one-tenth as long. Plates were sprayed with concentrated sulphuric acid and heated at 150~. Tosylates were identified by spraying with I yO dip
Anreicherung von Isotopen mittels Dünnschicht-Chromatographie
✍ Scribed by H. Specker; A. Hufnagel; R. Deibert
- Publisher
- Springer
- Year
- 1983
- Tongue
- English
- Weight
- 218 KB
- Volume
- 70
- Category
- Article
- ISSN
- 0028-1042
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
The thin layer method is applied to the separation and identification of the anions of several oxoacids of phosphorus.
Da es sich bei beiden Methoden um Einheitsmethoden handelt, werden wir den nach unserer Meinung zu kleinen Faktor bei Benutzung dieser Methoden weiterverwenden. Wir empfehlen die Nachprufung unserer Ergebnisse in anderen Laboratorien mit dem Ziel, dai3 der richtige Faktor in die Einheitsmethoden auf
## 2-(2'-ChZnolyl)-I-methyl-oxazol ( VZZe) . 6 g Azomethin VIe liess man langsam zu einer vorgekiihlten Losung von 8,5 g P,O, in 4 ml konz. H,SO, tropfendie Tcmperatur darf hierbei nicht iiber 0" steigenund erwarmte dann ca. 30 Min. auf 120'. Nach dem Abkiihlen goss man die dunkelbraune Reaktionsm
1. A method for the separation of substances by thin layer ionophoresis and by the two dimensional combination of thin layer ionophoresis and chromatography on glass plates is described.