𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Analysis of multiple-acquisition SSFP

✍ Scribed by Neal K. Bangerter; Brian A. Hargreaves; Shreyas S. Vasanawala; John M. Pauly; Garry E. Gold; Dwight G. Nishimura


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
842 KB
Volume
51
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Refocused steady‐state free precession (SSFP) is limited by its high sensitivity to local field variation, particularly at high field strengths or the long repetition times (TRs) necessary for high resolution. Several methods have been proposed to reduce SSFP banding artifact by combining multiple phase‐cycled SSFP acquisitions, each differing in how individual signal magnitudes and phases are combined. These include maximum‐intensity SSFP (MI‐SSFP) and complex‐sum SSFP (CS‐SSFP). The reduction in SSFP banding is accompanied by a loss in signal‐to‐noise ratio (SNR) efficiency. In this work a general framework for analyzing banding artifact reduction, contrast, and SNR of any multiple‐acquisition SSFP combination method is presented. A new sum‐of‐squares method is proposed, and a comparison is performed between each of the combination schemes. The sum‐of‐squares SSFP technique (SOS‐SSFP) delivers both robust banding artifact reduction and higher SNR efficiency than other multiple‐acquisition techniques, while preserving SSFP contrast. Magn Reson Med 51:1038–1047, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Multiple echo SSFP sequences
✍ Chris T. Mizumoto; Eiji Yoshitome 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 416 KB

## Abstract We report a new type of SSFP imaging sequences for acquiring higher‐order echoes. Spins excited during a cycle have, in a sense, a phase memory such that they can be refocused several cycles down the line, and since the spins are pulsed under a steady‐state condition, the resulting echo

Fast SSFP gradient echo sequence for sim
✍ S. Y. Lee; Z. H. Cho 📂 Article 📅 1988 🏛 John Wiley and Sons 🌐 English ⚖ 508 KB

Recently, the gradient echo imaging sequence in conjunction with small flip angle excitations and short repetition times has been widely used for fast NMR imaging. As the repetition time decreases to an extent comparable to the spin-spin relaxation time T2, the residual phase coherency of the transv

Analysis of the higher-order echoes in S
✍ D. J. Kim; Z. H. Cho 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 563 KB

In the steady-state free precession (SSFP) with an applied linear gradient, the transverse magnetizations are periodically distributed. Fourier analysis of this periodic distribution leads to the understanding of many interesting phenomena in SSFP. It is found that there are many other higher-order