𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Analysis of metallothioneins by means of capillary electrophoresis coupled to electrospray mass spectrometry with sheathless interfacing

✍ Scribed by Xu Guo; Hing Man Chan; Roger Guevremont; K. W. Michael Siu


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
84 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Capillary electrophoresis (CE) coupled to electrospray mass spectrometry via sheathless interfacing has been applied to the analysis of mammalian metallothionein (MT) extracts. In a rabbit-liver extract, four (MT-2C, MT-2A, MT-2D and MT-2E) out of six known MT sub-isoforms were unambiguously identified under three CE-resolved peaks. A fourth peak was found to contain MT-1A and/or MT-2B, whose molecular masses differ by only 1 Da. Traces of non-N-acetylated MT-2D and MT-2E were observed in a fifth, minor peak. In a rat-liver extract, both MT-1 and MT-2 were resolved and identified. Non-Nacetylated MT-2 was also identified in a resolved, minor peak. Minimum detectable amounts of MTs have been estimated to be approximately 0.6 fmol per sub-isoform.


πŸ“œ SIMILAR VOLUMES


Optimization of capillary electrophoresi
✍ Jenny Samskog; Magnus Wetterhall; Sven Jacobsson; Karin Markides πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 73 KB

When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be sui

A novel sheathless and electrodeless mic
✍ M. Mazereeuw; A.J.P. Hofte; U.R. Tjaden; J. van der Greef πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 206 KB πŸ‘ 1 views

A novel microelectrospray interface for the on-line coupling of capillary-zone electrophoresis (CZE) and mass spectrometry is described. The outlet of the fused-silica CZE capillary is tapered and serves as the microspray tip. The spray does not contain a sheath flow nor does the capillary tip conta

Packed capillary column liquid chromatog
✍ Benita Hyllbrant; Niklas Tyrefors; Bengt LΓ₯ngstrΓΆm; Karin E. Markides πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 89 KB πŸ‘ 1 views

When packed capillary columns are coupled to electrospray mass spectrometry, care must be taken to reduce the dead volumes of the detector connections. In this work, the coupling between the column and the detector was made with a 20-m i.d. fused silica capillary which was inserted in the electrospr

Analysis of a Standard Peptide Mixture b
✍ H. J. Major; A. E. Ashcroft πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 409 KB πŸ‘ 2 views

The combination of capillary electrophoresis with mass spectrometry allows efficient separation and identification of components in mixtures with greater specificity than can be obtained using capillary electrophoresis and ultra violet detection alone. For the mixture of peptides analysed in this ap

Determination of glycoalkaloids and rela
✍ Giuliana Bianco; Philippe Schmitt-Kopplin; Giuseppe De Benedetto; Antonius Kettr πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 191 KB πŸ‘ 1 views

Glycoalkaloids are naturally occurring nitrogen-containing compounds present in many species of the family Solanaceae, including cultivated and wild potatoes (Solanum spp.), tomatoes (Lycopersicon spp.), etc. These compounds have pharmacological and toxicological effects on humans due to their signi