𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Analysis of deprotonated acids with silicon nanoparticle-assisted laser desorption/ ionization mass spectrometry

✍ Scribed by Yimin Hua; Shai Dagan; Samanthi Wickramasekara; Dylan J. Boday; Vicki H. Wysocki


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
249 KB
Volume
45
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Chemically modified silicon nanoparticles were applied for the laser desorption/negative ionization of small acids. A series of substituted sulfonic acids and fatty acids was studied. Compared to desorption ionization on porous silicon (DIOS) and other matrix‐less laser desorption/ionization techniques, silicon nanoparticle‐assisted laser desorption/ionization (SPALDI) mass spectrometry allows for the analysis of acids in the negative ion mode without the observation of multimers or cation adducts. Using SPALDI, detection limits of many acids reached levels down to 50 pmol/µl. SPALDI of fatty acids with unmodified silicon nanoparticles was compared to SPALDI using the fluoroalkyl silylated silicon powder, with the unmodified particles showing better sensitivity for fatty acids, but with more low‐mass background due to impurities and surfactants in the untreated silicon powder. The fatty acids exhibited a size‐dependent response in both SPALDI and unmodified SPALDI, showing a signal intensity increase with the chain length of the fatty acids (C12‐C18), leveling off at chain lengths of C18‐C22. The size effect may be due to the crystallization of long chain fatty acids on the silicon. This hypothesis was further explored and supported by SPALDI of several, similar sized, unsaturated fatty acids with various crystallinities. Fatty acids in milk lipids and tick nymph samples were directly detected and their concentration ratios were determined by SPALDI mass spectrometry without complicated and time‐consuming purification and esterification required in the traditional analysis of fatty acids by gas chromatography (GC). These results suggest that SPALDI mass spectrometry has the potential application in fast screening for small acids in crude samples with minimal sample preparation. Copyright © 2010 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Quantitative Analysis of Oligonucleotide
✍ Bernd A. Bruenner; Tai-Tung Yip; T. William Hutchens 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 434 KB 👁 2 views

Quantitative aspects of oligonucleotide analysis by matrix-assisted laser desorption/iotion (MALDI) mass spectrometry remain largely unexplored relative to the efforts that have been devoted to quantitative peptide and protein analysis. The successful quantitation of these other biopolymers coupled

Effective detection of peptides containi
✍ Tomoya Kinumi; Yukiyasu Shimomae; Ryuichi Arakawa; Yoshiro Tatsu; Yasushi Shiger 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 226 KB

## Abstract Cysteine sulfonic acid‐containing peptides, being typical acidic peptides, exhibit low response in matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated fo

Analysis of wheat gluten proteins by mat
✍ Dworschak, Ragnar G.; Ens, Werner; Standing, Kenneth G.; Preston, Ken R.; Marchy 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 237 KB 👁 2 views

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) was used to analyze the protein composition in several common and durum wheat varieties. Mass spectra were obtained directly from crude and partially puriÐed wheat gliadin and reduced glutenin subunit fractions. Mass spectra of

Matrix Compatible Buffers for Analysis o
✍ Ute Kallweit; K. Olaf Börnsen; Gerhard M. Kresbach; H. Michael Widmer 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 506 KB

Different buffers typically used in biological applications were evaluated for compatibility with matrix-assisted laser desorptiodionization m a s spectrometry (MALDI-MS) measurements. It was found that the buffers recommended by Good and co-workers, such as HEPES and MOPS in concentrations below 5