Quantitative aspects of oligonucleotide analysis by matrix-assisted laser desorption/iotion (MALDI) mass spectrometry remain largely unexplored relative to the efforts that have been devoted to quantitative peptide and protein analysis. The successful quantitation of these other biopolymers coupled
Analysis of amphetamines and fentanyls by atmospheric pressure desorption/ionization on silicon mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry and its application to forensic analysis of drug seizures
✍ Scribed by Katja Pihlainen; Kestutis Grigoras; Sami Franssila; Raimo Ketola; Tapio Kotiaho; Risto Kostiainen
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 254 KB
- Volume
- 40
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.831
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The suitability of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP‐DIOS‐MS) and matrix‐assisted laser desorption ionization mass spectrometry (AP‐MALDI‐MS) for the identification of amphetamines and fentanyls in forensic samples was studied. With both ionization techniques, the mass spectra recorded showed abundant protonated molecules, and the background did not disturb the analysis. The use of tandem mass spectrometry (MS/MS) allowed unambiguous identification of the amphetamines and fentanyls. AP‐DIOS‐MS/MS and AP‐MALDI‐MS/MS were also successfully applied to the identification of authentic compounds from drug seizures. Common diluents and tablet materials did not disturb the analysis and compounds were unequivocally identified. The limits of detection (LODs) for amphetamines and fentanyls with AP‐DIOS‐MS/MS were 1–3 pmol, indicating excellent sensitivity of the method. The LODs with AP‐MALDI‐MS/MS were about 5–10 times higher. Copyright © 2005 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
We have developed a method to quantitatively attach quarternary ammonium fixed charge tags to the 5' or 3'NH 2 ends of DNA using N-hydroxysuccinimidyl ester chemistry. The chemical conditions for tagging were chosen so that tagging takes place exclusively on aliphatic NH 2 groups while base amino gr
## Abstract Matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) has been used to directly analyze and image pharmaceutical compounds in intact tissue. The anti‐tumor drug SCH 226374 was unambiguously determined in mouse tumor tissue using MALDI‐QqTOFMS (QSTAR) by monitoring the
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) was used to analyze the protein composition in several common and durum wheat varieties. Mass spectra were obtained directly from crude and partially puriÐed wheat gliadin and reduced glutenin subunit fractions. Mass spectra of
## Abstract Chemically modified silicon nanoparticles were applied for the laser desorption/negative ionization of small acids. A series of substituted sulfonic acids and fatty acids was studied. Compared to desorption ionization on porous silicon (DIOS) and other matrix‐less laser desorption/ioniz