An in vivo verification of the intravoxel incoherent motion effect in diffusion-weighted imaging of the abdomen
✍ Scribed by Andreas Lemke; Frederik B. Laun; Dirk Simon; Bram Stieltjes; Lothar R. Schad
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 316 KB
- Volume
- 64
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
To investigate the vascular contribution to the measured apparent diffusion coefficient and to validate the Intra Voxel Incoherent Motion theory, the signal as a function of the b‐value was measured in the healthy pancreas with and without suppression of the vascular component and under varying echo times (TE = 50, 70, and 100 msec). The perfusion fraction f and the diffusion coefficient D were extracted from the measured DW‐data using the original Intra Voxel Incoherent Motion‐equation and a modified version of this equation incorporating relaxation effects. First, the perfusion fraction f in the blood suppressed pancreatic tissue decreased significantly (P = 0.03), whereas the diffusion coefficient D did not change with suppression (P = 0.43). Second, the perfusion fraction f increased significantly with increasing echo time (P = 0.0025), whereas the relaxation time compensated perfusion fraction f′ showed no significant dependence on TE (P = 0.31). These results verify a vascular contribution to the diffusion weighted imaging measurement at low b values and support the Intra Voxel Incoherent Motion‐theory. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract A method of performing diffusion‐weighted imaging (DWI) and diffusion tensor imaging (DTI) of the fetal brain in utero is proposed. The major difficulty of performing diffusion imaging in utero is the presence of motion. By modifying conventional single‐shot spin‐echo echo‐planar DWI wi
## Abstract To evaluate the sensitivity of the intravoxel incoherent motion (IVIM) technique to changes in cerebral blood flow, we made measurements of IVIM parameters in rat brain under conditions of altered arterial pCO~2~. The arterial pCO~2~, was varied over a range which would be expected to c
## Abstract Cardiac diffusion MRI based on stimulated‐echo acquisition mode (STEAM) techniques is hampered by its inherent low signal‐to‐noise ratio (SNR) efficiency. Diffusion imaging using standard spin‐echo (SE) techniques, on the other hand, offers higher SNRs but has been considered impractica
## Abstract Nonuniformities of magnetic field gradients can cause serious artifacts in diffusion imaging. While it is well known that nonlinearities of the imaging gradients lead to image warping, those imperfections can also cause spatially dependent errors in the direction and magnitude of the di
## Abstract ## Purpose To show the signal intensity varies with shot number in diffusion‐weighted (DW) echo‐planar imaging (EPI) and affects apparent diffusion coefficient (ADC) calculation. ## Materials and Methods This prospective study was performed on 35 adult patients and 20 volunteers. Mea