๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

An Improved Method for the Analysis of Cryptosporidium parvum Oocysts by Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

โœ Scribed by SUSAN T. GLASSMEYER; MICHAEL W. WARE; FRANK W. SCHAEFER III; JODY A. SHOEMAKER; DAVID D. KRYAK


Book ID
109253532
Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
122 KB
Volume
0
Category
Article
ISSN
1066-5234

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Methods for the Analysis of Hydrocarbon
โœ Paul O. Danis; Dane E. Karr; Yansan Xiong; Kevin G. Owens ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 513 KB

With the addition of silver acetoacetonate to matrices of trans-3-indoleacrylic acid or 1,4-di-(2-(5-phenyloxazolyl))benzene, methods have been developed for the analysis of hydrocarbon polymers by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Silver-catio

Quantitative analysis of antibiotics by
โœ Yong-Chien Ling; Lihnian Lin; Yi-Ting Chen ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 242 KB ๐Ÿ‘ 2 views

Comparative studies of the matrix-assisted laser desorption/ionization (MALDI) of 30 antibiotics were made using a-cyano-4-hydroxycinnamic acid (HCCA), 2,5-dihydroxybenzoic acid (DHB), 5,10,15,20tetrakis(4-hydroxyphenyl)-21H,23H-porphyrin and meso-tetra(N-methyl-4-pyridyl)porphyrin matrices. Most an

Improved mass accuracy in matrix-assiste
โœ Ole Vorm; Matthias Mann ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 389 KB

One problem of matrix-assisted laser desorption ionization coupled to time-of-flight mass spectrometry is the moderate mass accuracy that typically can be obtained in routine applications, Here we report improved mass accuracy for peptides, even when low amounts and complex peptide mixtures are used

The Use of a Co-matrix for Improved Anal
โœ Tracey A. Simmons; Patrick A. Limbach ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 115 KB ๐Ÿ‘ 2 views

Cation adduction to oligonucleotides and nucleic acids during mass spectrometric analysis is a recurrent problem. We have found that the use of organic base solutions of high gas-phase proton affinity, as used previously in electrospray ionization mass spectrometry, can significantly reduce the cati

Analysis of solid-supported oligonucleot
โœ Albert Meyer; Nicolas Spinelli; Jean-Louis Imbach; Jean-Jacques Vasseur ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 134 KB ๐Ÿ‘ 2 views

This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative o