𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Amperometric determination of peroxides by glassy carbon electrodes modified with copper-phenanthroline complexes

✍ Scribed by Rosanna Toniolo; Nicola Comisso; Gino Bontempelli; Gilberto Schiavon


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
888 KB
Volume
8
Category
Article
ISSN
1040-0397

No coin nor oath required. For personal study only.

✦ Synopsis


An amperometric sensor is described for the determination of peroxides in both aqueous and organic media. It consists of a rotating glassy carbon electrode modified by coating first with a thin film of a perfluorinated anionic exchanger (Tosflex) and then by immobilizing on this substrate the mixed-ligand copper complex [CuL,12+ with 1 ,lo-phenanthroline and bathophenanthroline (i.e., 1,lO-phenanthroline containing two phenyl-sulfonic groups as substituents in the positions 4 and 7), thanks to the bonds formed between the -NR: cationic groups of the Tosflex coating film and the -SOT anionic groups present in the latter ligand. The modified electrode, which is rather stable with time and can be easily restored, permits detection of peroxides by their reduction at less cathodic potentials than at an unmodified electrode surface. It shows enhanced sensitivity in a variety of media (water, ethanol and ethanol-toluene 60/40 v./v.) which were investigated in view of their ability, on the whole, to dissolve peroxides originally present in different natural samples. Its satisfactory performance, which is unaffected by the presence of oxygen in the sample, in all the media studied is reported for hydrogen peroxide and tert-butyl hydroperoxide in terms of detection limits, dynamic ranges and response time. Its application to the direct determination of peroxides in some cereal oils was also attempted and the results found are compared with those obtained by conventional methods.


πŸ“œ SIMILAR VOLUMES


CuO Crystalline Modified Glassy Carbon E
✍ Prof. Dr. Xiangqin Lin; Zhenhui Jing πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 104 KB πŸ‘ 1 views

As an alternative selection of electrocatalytic surface modifier, the electrochemically generated copper oxides is reinvestigated by using cyclic voltammetry (CV), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Interesting phenomena have been found, which indicate tha

Amperometric Detection of Morphine at Pr
✍ Abdollah Salimi; Rahman Hallaj; Gholam-Reza Khayatian πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 485 KB πŸ‘ 2 views

## Abstract A highly sensitive and fast responding sensor for the determination of morphine is described. The multiwall carbon nanotubes immobilize on preheated glassy carbon electrode (5β€…min at 50 °C) by gently rubbing of electrode surface on a filter paper supporting the carbon nanotubes.The resu

Determination of Nitric Oxide by Glassy
✍ Tang Xiaorong; Fang Cheng; Yao Bing; Zhang Wuming πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 66 KB

Nitric oxide can be oxidized to NO 2 Οͺ (then to NO 3 Οͺ ) and reduced to N 2 O at a glassy carbon electrode modified with the film of poly(neutral red). When the modified electrode is further coated with a thin Nafion film, the interference of NO 2 Οͺ can be almost thoroughly eliminated, and the elect