𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Alternating current adsorptive stripping voltammetry in a flow system for the determination of ultratrace amounts of folic acid

✍ Scribed by Jilin Han; Hongyuan Chen; Hong Gao


Publisher
Elsevier Science
Year
1991
Tongue
English
Weight
528 KB
Volume
252
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


The adsorptive behaviour of folic acid on the surface of a mercury electrode was investigated and the surface rate constant of electrochemical reaction was determined (k, = 440 s-', 25Β°C). Adsorptive stripping voltammetry was applied to a flow system for the determination of ultratrace amounts of folic acid. The effects of various parameters, for e.g., flow-rate, flow time of solution and accumulation potential, on peak currents are discussed. Interferences from the test solution can be eliminated by the technique of medium exchange. The peak current is proportional to the concentration of folic acid in the range of 1O-8-1O-" mol I-' with a correlation coefficient of 0.998. The relative standard deviation is 2.5% at a concentration of 2.8 X lo-* mol I-' (7 determinations). The detection limit of a.c. adsorptive stripping voltammetry is as low as 2 x lo-l2 mol I-' (lo-min accumulation).


πŸ“œ SIMILAR VOLUMES


Determination of metals in a multicompon
✍ Clinio Locatelii; Ermanno Vasca; Corrado Bighi; Francesco Fagioli; Tibor Garai πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 487 KB πŸ‘ 2 views

## Abstract A combination of sensitive and selective voltammetric methods, namely differential pulse (DPASV) and fundamental and second harmonic alternating current anodic stripping voltammetry (ACASV) were found to be very suitable techniques for the simultaneous determination of metal species hav

Determination of mitoxantrone using phas
✍ Juan Carlos Cortina Villar; Agustin Costa GarcΓ­a; Paulino TuΓ±on Blanco πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 538 KB

A flow cell mcorporatmg a stationary carbon paste electrode coupled with a c voltammetry was used Preconcentratlon and determmatlon of the cancer chemotherapy drug mltoxantrone (MXT) were achieved via a flow-mjectlon approach utlhzmg adsorptton of the drug on the electrode, followed by medmm exchang

Application of second harmonic alternati
✍ Francesco Fagioli; Clinio Locatelli; Silvio Landi; Roberto Vecchietti πŸ“‚ Article πŸ“… 1989 πŸ› John Wiley and Sons 🌐 English βš– 465 KB πŸ‘ 2 views

Second harmonic alternating current voltammetry coupled with anodic stripping techniques has been used for the simultaneous determination of lead(II), tin(II), and thallium( I) (elements which, in common supporting electrolytes exhibit similar half-wave potentials). The supporting electrolyte was 0.

Application of square-wave voltammetry f
✍ Ying-Sing Fung; Song-Ying Mo πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 537 KB

The application of square-wave voltammetly for detection m the flow-mJection determmatlon of ascorlxc acid m soft drinks and fruit Jmces was mvestlgated The pH of the solution was buffered at 2 87 to stabdlze the ascorbic acid pnor to analysis Parameters such as scan rate, square-wave amphtude, step