𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Aerobic biological treatment of waste- waters containing dichloromethane

✍ Scribed by Sandra C Moura; Ruben Ferreira Jorge; Anouk Duque; Rui AR Boaventura; Paula ML Castro


Publisher
Wiley (John Wiley & Sons)
Year
2007
Tongue
English
Weight
241 KB
Volume
82
Category
Article
ISSN
0268-2575

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

BACKGROUND: Volatilization has been advanced as one of the predominant phenomena contributing to volatile organic carbon emissions from wastewater treatment plants (WWTPs). In this study, strategies for minimizing such air stripping losses when treating a liquid stream containing dichloromethane (DCM), aiming at decreasing the overall emission inventory from WWTPs, were investigated.

RESULTS: System R1, consisting of a continuous flow stirred tank reactor (CSTR) treating a liquid stream containing DCM at a concentration of 12 mmol dm^βˆ’3^ presented a biodegradation efficiency (BE) of 68%, based upon chloride release, with 10% of measurable losses, mainly due to volatilization, and 22% of unmeasurable losses. System R2 introduced operational designs aiming at decreasing DCM volatilization. In Experiment R2.1, a biotrickling filter, through which the air stripped from the CSTR was driven, was introduced leading to a reduction from 10% to 7% on the measurable losses. In Experiment R2.2, the air stripped from the CSTR was recirculated at a flow rate of 2.4 dm^3^ h^βˆ’1^ through the reactor medium before entering the biotrickling filter. The BE was improved from 69% to 82% and the losses associated with air stripping were successfully reduced to 2%. The proposed design, including air recirculation and the biotrickling filter, increased the ratio between the biodegradation rate and the volatilization rate from 7 to 41.

CONCLUSIONS: Recirculation of the gaseous effluent through the reactor medium, which allowed for higher residence time within the bioreactor, was shown to be a successful strategy for improving the treatment process, thus minimizing DCM volatilization losses. Copyright Β© 2007 Society of Chemical Industry


πŸ“œ SIMILAR VOLUMES


Biological treatment of pharmaceutical w
✍ W. Wesley Eckenfelder JR.; Edwin L. Barnhart πŸ“‚ Article πŸ“… 1962 πŸ› John Wiley and Sons 🌐 English βš– 421 KB πŸ‘ 1 views
Treatment of laundry waste-water by elec
✍ Fatemeh Janpoor; Ali Torabian; Vahid Khatibikamal πŸ“‚ Article πŸ“… 2011 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 227 KB πŸ‘ 1 views

## Abstract **BACKGROUND:** The present study describes an electrocoagulation process for treating laundry waste‐water using aluminum plates. The effect of various parameters such pH, voltage, hydraulic retention time (HRT), and number of aluminum plates between the anode and cathode on efficiency

Controlled Filtration of Waste Water Con
✍ Paleni, A. πŸ“‚ Article πŸ“… 1966 πŸ› John Wiley and Sons βš– 198 KB

Es liegen Berichte vor, nach denen mit einer solchen Anlage jahrlich 60 000 kg Wollfett erzeugt wurden. Dieses entspricht bei einem Preis je kg Fett von DM 1.70 einer Einnahme von DM 102000.--. Einnahme DM 102000.-Unkosten DM 26250.-Gewinn pro Jahr DM 75750.-Die Qualitat des rnit einer Westfalia-Anl