## Abstract Wear debris‐induced osteolysis is the major cause of aseptic loosening and failure of hip implants. One of the promising therapeutic interventions to improve the longevity of hip implants is to administrate bisphosphonate drug to inhibit osteoclastic bone resorption. This study aimed at
Adherent apatite coating on titanium substrate using chemical deposition
✍ Scribed by R. Rohanizadeh; R.Z. LeGeros; M. Harsono; A. Bendavid
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 397 KB
- Volume
- 72A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Plasma‐sprayed “HA” coatings on commercial orthopedic and dental implants consist of mixtures of calcium phosphate phases, predominantly a crystalline calcium phosphate phase, hydroxyapatite (HA) and an amorphous calcium phosphate (ACP) with varying HA/ACP ratios. Alternatives to the plasma‐spray method are being explored because of some of its disadvantages. The purpose of this study was to deposit an adherent apatite coating on titanium substrate using a two‐step method. First, titanium substrates were immersed in acidic solution of calcium phosphate resulting in the deposition of a monetite (CaHPO~4~) coating. Second, the monetite crystals were transformed to apatite by hydrolysis in NaOH solution. Composition and morphology of the initial and final coatings were identified using X‐ray diffraction (XRD), Scanning Electron Microscopy, and Energy Dispersive Spectroscopy (EDS). The final coating was porous and the apatite crystals were agglomerated and followed the outline of the large monetite crystals. EDS revealed the presence of calcium and phosphorous elements on the titanium substrate after removing the coating using tensile or scratching tests. The average tensile bond of the coating was 5.2 MPa and cohesion failures were observed more frequently than adhesion failures. The coating adhesion measured using scratch test with a 200‐μm‐radius stylus was 13.1N. Images from the scratch tracks demonstrated that the coating materials were squashed without fracturing inside and/or at the border of the tracks until the failure point of the coating. In conclusion, this study showed the potential of a chemical deposition method for depositing a coating consisting of either monetite or apatite. This method has the advantage of producing a coating with homogenous composition on even implants of complex geometry or porosity. This method involves low temperatures and, therefore, can allow the incorporation of growth factors or biogenic molecules. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 72A: 428–438, 2005
📜 SIMILAR VOLUMES
## Abstract In previous investigations, a simple method, precalcification, was developed for bioactivating titanium. After a titanium sample was precalcified in a boiling saturated Ca(OH)~2~ solution and then immersed in a calcium phosphate supersaturated solution, an apatite coating rapidly precip
The surfaces of hydroxyapatite-glass-titanium Especially the pull-out strengths of surface-treated speci-(HA-G-Ti) functionally gradient composite and titanium bars mens were significantly larger than the untreated ones at 3 were treated with electrochemical apatite deposition, and a weeks after imp
## Abstract The electrostatic spray deposition (ESD) technique offers the possibility of depositing calcium phosphate (CaP) coatings onto various substrate materials with defined chemical and morphological properties. The relationship between physical, apparatus‐related deposition parameters, and t
## Abstract In this study, a novel nano‐micro structured octacalcium phosphate/protein (OCP/protein) composite coating has been successfully constructed on titanium substrate by using an electrochemically induced deposition technique. The structure and composition of the composite coating were inve