## Abstract ## Purpose The aim of this study was to compare the value of absolute and relative renal length (ARL and RRL, respectively) measurements in determining variations in normal kidney size related to sex, body height, and increasing age among patients older than 60 years. ## Methods Kidn
Accuracy of sonographic volume measurements of kidney transplant
β Scribed by Marcello Mancini; Pier Paolo Mainenti; Antonio Speranza; Raffaele Liuzzi; Ernesto Soscia; Massimo Sabbatini; Liberato Aldo Ferrara; Stefano Federico; Marco Salvatore
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 137 KB
- Volume
- 34
- Category
- Article
- ISSN
- 0091-2751
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Purpose.
Sonographic measurement of renal volume is one of the parameters used in the diagnosis of renal transplant dysfunction and in followβup of patients with renal transplant. The aim of this study was to compare the prolate ellipsoid formula with a new formula in calculating the volume of a transplanted kidney.
Methods.
The renal volumes in 24 patients with a stable renal transplant were determined sonographically with the ellipsoid formula and via helical CT with the voxelβcount method, which is the gold standard. A new formula that uses renal length and the crossβsectional area at the maximum transverse section has been evaluated in a small series of transplanted kidneys.
Results.
Renal volume was underestimated with the sonographic ellipsoid formula and the new formula. The new formula yielded the lowest underestimation of the mean renal volume, and the measurements obtained with it were not significantly different from those obtained with CT.
Conclusions.
The use of sonography is appropriate for accurate calculation of renal volume, and the new formula that uses only 2 ultrasound parameters best represents the volume of a renal transplant. Β© 2006 Wiley Periodicals, Inc. J Clin Ultrasound 34:184β189, 2006
π SIMILAR VOLUMES
Variations have been observed in the measurement of fetal femoral dia- physis length by ultrasound. This in vitro study examines the effect of depth, the angle of the bone relative to the axis of the sound beam, the machine, and the observer on the precision of measurement. Using analysis of varianc
Fetal renal size late in the first trimester of pregnancy was evaluated by transvaginal ultrasonography in 50 patients not at risk for congenital kidney disease and whose pregnancies resulted in a normal outcome. Both kidneys were reliably identified in all patients scanned at 12 weeks, 13 weeks, an
## Abstract ## Purpose The purposes of this study were first to prospectively evaluate the feasibility of using sonographic measurements of volume of the ossified part of the calcaneus to determine skeletal age in healthy children and second, to provide normal ranges of this volume by sex and age
## Abstract ## Purpose The aim of this study was to evaluate the accuracy of sonography for measuring the volume of the left lateral segment of the liver. ## Methods The volume of the left lateral segment of the liver was measured with sonography in 101 consecutive patients who were hospitalized