A pulsed Er:YAG laser (2.94 pm) was used to determine ablation depths per pulse of laser energy at 2 Hz and 5 Hz in human teeth cross sections of enamel and dentin. Ablation depths per pulse at 2 Hz in enamel of intact human teeth were measured and compared to ablation depths per pulse determined in
Ablation of composite resins using Er:YAG laser—comparison with enamel and dentin
✍ Scribed by Rosane de F.Z. Lizarelli; Lilian T. Moriyama; Vanderlei S. Bagnato
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 207 KB
- Volume
- 33
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Objectives
The purpose of this work is to investigate comparative ablation rate between composite resins and dental hard tissues (enamel and dentin) after Er:YAG laser irradiation to verify possible development of an ultra‐conservative dentistry to with minimum effect for the teeth tissue.
Methods
We have used 11 extracted or exfoliated primary anterior and posterior teeth and six extracted permanent molar teeth. Three different types of composite resin were chosen (microfiller, hybrid, and condensable) in terms of chemical and structural composition. Composite tablets and the teeth were irradiated with a Er:YAG laser at different laser beam energy level per pulse (100, 200, 300, and 400 mJ). Diameter and depth of each resulted microcavity were measured and the material removed volumes were calculated. The resulted values were plotted and fitted to allow a comparative observation of the material removed as a function of energy level per pulse.
Results
While the idea of ultra‐conservative dentistry seems to apply well for enamel of primary and permanent teeth, at the present stage it does not apply well for primary or permanent dentin. For dentin, the composition and content of water makes the Er:YAG laser ablation equal or superior in rate compared with the three used resins.
Significance
This work presents of a comparative study of Er:YAG laser ablation, allowing to analyze the possible selective ablation between composite resin placed and cured and dental hard tissues, with the goal to propose a new clinical technique: differential ablation for composite resin restorations using Er:YAG laser. Lasers Surg. Med. 33:132–139, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Background and Objectives This in vitro study evaluated the influence of a flowable composite resin (FCR) on the tensile bond strength of resin to dentin treated with the Er:YAG Laser (L) and diamond bur (DB). ## Study Design/Materials and Methods Ninety dentin surfaces obtained f
## Abstract ## Background and Objectives The investigation of adhesion between an Er:YAG laser‐irradiated surface and composite resin is very important to ensure the best clinical results. The purpose of this investigation is to determine if the application of various treatments on Er:YAG laser‐ir
## Abstract ## Background and Objective We have reported that the application of ultrasonic scalers on the Er:YAG laser‐irradiated enamel surface achieved bond strengths of approximately 16 MPa. However, it is reported that a bond strength of 20 MPa is needed to prevent the maginal gaps, so the te
## Abstract The purpose of this study was to assess the influence of Er:YAG laser pulse repetition rate on the thermal alterations occurring during laser ablation of sound and demineralized primary dentin. The morphological changes at the lased areas were examined by scanning electronic microscopy
__Objective:__ The purpose of this study is to make use of scanning electron microscopy in order to comparatively analyze the morphological alterations to human and bovine enamel and dentin. __Earlier data:__ Many a morphological study involving Er:YAG laser can be found in the literature. Still, no