Background and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser. Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phospho
Tensile bond strength of a flowable composite resin to ER:YAG-laser-treated dentin
✍ Scribed by Juliana Donadio-Moura; Sheila Gouw-Soares; Patricia M. de Freitas; Ricardo S. Navarro; Lynn G. Powell; Carlos de P. Eduardo
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 67 KB
- Volume
- 36
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Background and Objectives
This in vitro study evaluated the influence of a flowable composite resin (FCR) on the tensile bond strength of resin to dentin treated with the Er:YAG Laser (L) and diamond bur (DB).
Study Design/Materials and Methods
Ninety dentin surfaces obtained from 45 third molars were ground and randomly divided into six groups (n = 15): G1–DB, G2–DB+FCR, G3–L (100 mJ, 10 Hz, 37.04 J/cm^2^), G4–L (100 mJ, 10 Hz, 37.04 J/cm^2^)+FCR, G5–L (250 mJ, 2 Hz, 92.60 J/cm^2^), and G6–L (250 mJ, 2 Hz, 92.60 J/cm^2^)+FCR. After surface etching with 37% phosphoric acid and the application of an adhesive system, inverted conical specimens were prepared with a hybrid composite resin. In groups G2, G4, and G6 a FCR was placed before the hybrid composite resin. After 24 hours‐storage in distilled water, the tensile test was performed in a universal testing machine (0.5 mm/minute, 500 N).
Results
Data were submitted to Kruskal Wallis test (P = 0.01). The mean bond strength values (MPa±SD) were: G1–13.54 (±2.99), G2–14.67 (±2.32), G3–9.49 (±3.09), G4–14.60 (±2.76), G5–8.97 (±3.89), and G6–13.02 (±2.18). Groups G1 and G2 presented the highest bond strength values, which were statistically similar to those of G4 and G6. The groups treated with laser and without the FCR (G3 and G5) showed the lowest shear bond strength values.
Conclusions
FCR can increase the adhesion to dentin treated with Er:YAG laser within different parameters. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The study evaluated the __in vitro__ influence of pulse‐repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin–resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superfic
## Abstract ## Background and Objective We have reported that the application of ultrasonic scalers on the Er:YAG laser‐irradiated enamel surface achieved bond strengths of approximately 16 MPa. However, it is reported that a bond strength of 20 MPa is needed to prevent the maginal gaps, so the te
## Abstract ## Background and Objectives To assess the effect of erbium:yttrium aluminium garnet (Er:YAG) laser on bond strength to dentin of a self‐etching primer (Clearfil Liner Bond 2V, CL2V) and two single‐bottle agents (Excite, EX; Gluma One Bond, GB). ## Study Design/Materials and Methods
## Abstract ## Background and Objectives The purpose of this study was to assess the performances of a single‐component adhesive system when an Er:YAG laser was used to prepare cavities. ## Study Design/Materials and Methods Shear bond strength tests were performed on composite rods bonded with
## Abstract ## Background and Objectives This study aimed to assess in vitro the influence of Er:YAG laser energy on the shear bond strength of a total‐etch adhesive to lased dentin of primary teeth, and observe under SEM the morphological appearance of laser‐ablated dentin surfaces. ## Study Des