โœฆ Synopsis


Abstract

Window diagrams that optimize for the separation of only one or a few components in a complex mixture are applied to onโ€line process analysis when speed of analysis is more important than a complete separation of all components in the sample. A window diagram based on retention indexes is the most useful for quickly evaluating the feasibility of a given pair of phases. The one with the most useful output is one based on partition ratios, as this can be used directly with the columns in hand. A PCโ€based spreadsheet program with integral specific retention volume data for the common liquid phases is described as a tool for selecting the optimum ratio of lengths for the columns in hand.


๐Ÿ“œ SIMILAR VOLUMES


A rapid and sensitive method for the ana
โœ Martin F. Chaplin ๐Ÿ“‚ Article ๐Ÿ“… 1982 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 490 KB

A rapid and simple gas-liquid chromatographic method for the determination of subnanomolar amounts of carbohydrates derived from glycoproteins is described. The procedure involves methanolysis in the presence of methyl acetate followed by removal of hydrogen chloride by c~va~ration with t-butyl alco

A continuous liquid-liquid extraction sy
โœ Goosens, Elise C. ;de Jong, Dirk ;de Jong, Gerhardus J. ;Brinkman, Udo A. Th. ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 658 KB

## Abstract The applicability of a liquidโ€liquid extraction system which is coupled onโ€line with a capillary gas chromatograph was studied for environmental and ecotoxicological analyses. The optimized and automated system was used for the determination of apolar and rather nonโ€volatile organic com

Continuous liquid-liquid extraction comb
โœ Goosens, Elise C. ;Jong, Dirk De ;de Jong, Gerhardus J. ;Rinkema, Feddy D. ;Brin ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 601 KB

The on-line coupling of a Liquid-liquid extraction system with capillary gas chromatography using atomic emission detection (GC-AED) has been studied. The required large volumes of about 100 pl of an iso-octane solution can be introduced into the GC-AED system by using the AED solvent vent and a sol

On-line coupling of liquid chromatograph
โœ Modeste, Fabrice ;Caude, Marcel ;Devaux, Philippe ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 805 KB

## Abstract The following paper presents a fast, selective, sensitive, and automated procedure for the residue analysis of the pyrethroid insecticide acrinathrin in various fruit samples by onโ€line combination of Liquid Chromatography (LC) with capillary Gas Chromatography (GC) and an Electronโ€Capt

On-line preconcentration microliquid chr
โœ A. J. Oosterkamp; M. Carrascal; D. Closa; G. Escolar; E. Gelpi; J. Abian ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 196 KB

## Abstract The practical limitations of miniaturized liquid chromatography (LC) methods for the analysis of endogenous peptides in plasma samples are studied. An automatic column switching method is used for onโ€line micropreconcentration and microLCโ€MSโ€“MS (mass spectrometry) analysis of bradykinin