✦ Synopsis


Abstract

A water and fat separation technique based on a three‐point Dixon method using two‐dimensional (2D) and three‐dimensional (3D) gradient‐echo sequences and a new phase‐unwrapping approach is presented. Using velocity‐compensated sequences, three images, with water and fat protons in phase, opposed phase, and in phase, were acquired in an interleaved fashion for each phase‐encoding line of the image. A fast 2D scan permitted acquisition of images within a single breathhold, eliminating respiratory motion artifacts. The 3D sequence allowed coverage of a large region of interest with thin, contiguous slices. To correct field inhomogeneity effects, phase unwrapping was required. This was accomplished by comparing the corresponding pixels in the two water and fat in‐phase images on a pixel‐by‐pixel basis. This phase‐unwrapping approach is faster, more reliable, and requires less user interfacing than other methods. The water and fat separation method performed well in various parts of the body.


📜 SIMILAR VOLUMES


A single-point dixon technique for fat-s
✍ Jingfei Ma 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 504 KB

## Abstract ## Purpose To develop a single‐point Dixon (SPD) technique that requires only data of a single echo with a flexible echo time, and to demonstrate its use for fat‐suppressed, T1‐weighted contrast agent enhancement studies. ## Materials and Methods Raw data were collected using a produ

Measurement of fat/water ratios in rat l
✍ Xiaowei Zhang; Mark Tengowski; Lisa Fasulo; Suzanne Botts; Steve A. Suddarth; G. 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 522 KB

## Abstract Hepatic steatosis, or fatty liver, is commonly observed during the animal phase of drug safety studies. A noninvasive three‐dimensional (3D) three‐point Dixon method was used to quantitatively evaluate the fatty livers of rats induced by an experimental microsomal transfer protein (MTP)

Separation of fat and water in fast spin
✍ Peter A. Hardy; R. Scott Hinks; Jean A. Tkach 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 555 KB

## Abstract A method for suppressing fat in fast spin‐echo imaging with the three‐point Dixon technique is described. The method differs from the three‐point Dixon method used in conventional spin‐echo imaging in that the readout gradient instead of a radio‐frequency pulse is shifted. This method p

Pilot study of improved lesion character
✍ Catherine J. Moran; Frederick Kelcz; Youngkyoo Jung; Ethan K. Brodsky; Sean B. F 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 634 KB

## Abstract ## Purpose To assess a 3D radial balanced steady‐state free precession (SSFP) technique that provides submillimeter isotropic resolution and inherently registered fat and water image volumes in comparison to conventional T2‐weighted RARE imaging for lesion characterization in breast ma