𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A single-point dixon technique for fat-suppressed fast 3D gradient-echo imaging with a flexible echo time

✍ Scribed by Jingfei Ma


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
504 KB
Volume
27
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To develop a single‐point Dixon (SPD) technique that requires only data of a single echo with a flexible echo time, and to demonstrate its use for fat‐suppressed, T1‐weighted contrast agent enhancement studies.

Materials and Methods

Raw data were collected using a product fast 3D gradient‐echo pulse sequence. Phase‐error removal and fat‐suppression (FS) were achieved using a fully‐automated region‐growing algorithm. A water and fat phantom and the abdomen and breast of cancer patients before and after injection of gadolinium contrast agent were imaged at varying echo times. Scan time efficiency and overall FS quality were compared to those by the product fast 3D gradient‐echo technique with conventional FS.

Results

In phantom, the SPD technique achieved uniform FS for a wide range of echo times corresponding to the water and fat relative phase angles between 100° and 160°. In patients, the technique was able to achieve approximately 30% scan time reduction and more uniform FS when compared to using the conventional FS technique but otherwise identical scan parameters.

Conclusion

The SPD technique compares favorably in scan time efficiency and FS uniformity and can be useful for fast T1‐weighted and fat‐suppressed imaging with contrast agent administration. J. Magn. Reson. Imaging 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


A three-point dixon method for water and
✍ Yi Wang; Debiao Li; E. Mark Haacke; Jeffrey J. Brown 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 934 KB

## Abstract A water and fat separation technique based on a three‐point Dixon method using two‐dimensional (2D) and three‐dimensional (3D) gradient‐echo sequences and a new phase‐unwrapping approach is presented. Using velocity‐compensated sequences, three images, with water and fat protons in phas

Separation of fat and water in fast spin
✍ Peter A. Hardy; R. Scott Hinks; Jean A. Tkach 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 555 KB

## Abstract A method for suppressing fat in fast spin‐echo imaging with the three‐point Dixon technique is described. The method differs from the three‐point Dixon method used in conventional spin‐echo imaging in that the readout gradient instead of a radio‐frequency pulse is shifted. This method p

Fast spin-echo triple-echo Dixon: Initia
✍ Russell N. Low; Jingfei Ma; Neeraj Panchal 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 677 KB

## Abstract ## Purpose To evaluate a prototype fast spin echo (FSE) triple‐echo‐Dixon (fTED) technique for breath‐hold, fat‐suppressed, T2‐weighted abdominal imaging. ## Materials and Methods Forty patients underwent breath‐hold T2‐weighted abdominal imaging with fTED and conventional fast recov

T2-weighted 3D fast spin echo imaging wi
✍ Ananth J. Madhuranthakam; Huanzhou Yu; Ann Shimakawa; Reed F. Busse; Martin P. S 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 375 KB

## Abstract ## Purpose: To develop a robust 3D fast spin echo (FSE) T~2~‐weighted imaging method with uniform water and fat separation in a single acquisition, amenable to high‐quality multiplanar reformations. ## Materials and Methods: The Iterative Decomposition of water and fat with Echo Asym

Breath-hold water and fat imaging using
✍ Jingfei Ma 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 199 KB

## Abstract A two‐point Dixon technique using a novel phase‐correction algorithm and commercially available dual‐echo fast gradient‐echo pulse sequence is presented. The phase‐correction algorithm determines the directional rather than phase distribution of signals due to field inhomogeneities. Spe

Three-dimensional fast spoiled gradient-
✍ Russell N. Low; Neeraj Panchal; Anthony T. Vu; Adrian Knowles; Lloyd Estkowski; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 796 KB

## Abstract ## Purpose To compare three‐dimensional fast spoiled gradient‐echo dual‐echo (3D‐FSPGR‐DE) with water reconstruction to conventional 3D‐FSPGR for gadolinium‐enhanced abdominal imaging. ## Materials and Methods Sixty‐five patients underwent abdominal MRI on a 1.5T GE‐HDx MR scanner us