𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling

✍ Scribed by Wen-Chau Wu; María Fernández-Seara; John A. Detre; Felix W. Wehrli; Jiongjiong Wang


Book ID
102954013
Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
633 KB
Volume
58
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Arterial spin labeling (ASL) is capable of noninvasively measuring blood flow by magnetically tagging the protons in arterial blood, which has been conventionally achieved using instantaneous (PASL) or continuous (CASL) RF pulses. As an intermediate method, pseudocontinuous ASL (pCASL) utilizes a train of discrete RF pulses to mimic continuous tagging that is often unavailable on imagers due to the requirement of continuous RF transmit capabilities. In the present study, we implemented two versions of pCASL (balanced and unbalanced gradient waveforms in tag and control scans) for both transmit/receive coils and array receivers. Experimental data show a 50% ± 4% increase of signal‐to‐noise ratio (SNR) compared with PASL and a higher tagging efficiency than amplitude‐modulated (AM) CASL (80% vs. 68%). Computer simulations predict an optimal tagging efficiency of 85% for flow velocities from 10 to 60 cm/s. It is theoretically and experimentally demonstrated that the tagging efficiency of pCASL is dependent upon the resonance offset and flip angle of the RF pulse train. We conclude that pCASL has the potential of combining the merits of PASL, including less hardware demand and higher tagging efficiency, and CASL, which includes a longer tagging bolus and thus higher SNR. These improvements provide a better balance between tagging efficiency and SNR. Magn Reson Med 58:1020–1027, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Theoretical and experimental evaluation
✍ Rolf Pohmann; Juliane Budde; Edward J. Auerbach; Gregor Adriany; Kâmil Uğurbil 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 468 KB

## Abstract Continuous arterial spin labeling is known to be the most sensitive arterial spin labeling technique. To avoid magnetization transfer effects and to overcome hardware limitations, several sequences have been proposed that adiabatically label the inflowing blood. Four of these methods ar

Theoretical analysis of the effect of im
✍ Shella D. Keilholz-George; Jack Knight-Scott; Stuart S. Berr 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 231 KB

Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependen

A theoretical and experimental compariso
✍ Eric C. Wong; Richard B. Buxton; Lawrence R. Frank 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 836 KB

Under ideal conditions, continuous arterial spin labeling (ASL) techniques are higher in SNR than pulsed ASL techniques by a factor of e. Presented here is a direct theoretical and experimental comparison of continuous ASL and pulsed ASL, using versions of both that are amenable to multislice imagin